![Banner SX5 Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/banner/sx5/sx5_instruction-manual_3759267068.webp)
5. Define the Timeout (minutes).
This parameter allows the entering of a muting backdoor timer (maximum time to stay muted). The default time limit
is 10 minutes. The time limit can be increased from 10 minutes to 1080 minutes in 1 minute increments. For no time
limit, enter 0.
WARNING: Select an infinite time for the Muting Time Limit only if the possibility of an
inappropriate or unintended mute cycle is minimized as determined and allowed by the
machine's risk assessment. The user is responsible to make sure that this does not create a
hazardous situation.
6. Enable or disable Override.
If muting is enabled, an override function can also be enabled. The override allows OSSDs to be manually forced on
to drive an item out of the Safety Zone.
WARNING: Measures must be taken to prevent activation of the mute-depended override
function from a fault or inadvertent operation of the initiating device.
7. Set the Override Mode, if applicable.
The only override mode available in the basic model is the single-line pattern. This is a single input to force the
scanner's OSSD output on. The hazardous motion should not start until the initiation button of the machine is also
engaged. The override time limit is 120 seconds.
8. In the Input Signals section, assign pins 1, 3, and 4 as a Reset, Restart 1, Restart 1 Reset, Muting Enable, Muting 1
1, Muting 1 2, or an Override 1 1 input depending on the configuration.
• Reset—The reset input function can be added in Automatic or manual reset mode. The reset input allows
restoring normal operation after a failure lockout (fault) condition, due to system error, without disconnecting the
power.
• Restart 1—The restart input function is only added in manual reset mode. The restart input turns on the OSSD
outputs after the blockage has been removed from the Safety Zone (and at startup).
• Restart 1 Reset—This selection will perform whichever input is needed at the moment (reset for faults, restart for
manual reset situations).
This parameter group assigns the signals of the input functions to the scanner pins. Each pin is also associated with
color-coded cable wiring, according to safety equipment regulations and standards. Previously assigned pins are
grayed out.
Click on the white > arrow in the upper right corner to move to the next configuration screen. Click on the white < to return
to the previous screen.
SX5 Safety Laser Scanner
68
www.bannerengineering.com - Tel: +1.763.544.3164