![Banner SX5 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/banner/sx5/sx5_instruction-manual_3759267038.webp)
1. Remove the M4 roll adjustment screws and washers (7), then align the M5 wall mounting screws (9).
2. Mount the roll adjustment bracket (8) to the wall or panel by inserting two M5 UNI 5933 screws (9). Tighten them,
alternating between the two, until they are tight (torque to 2.5 to 3 N·m).
3. Place the assembly of (1) and (6) back onto the roll adjustment bracket (8) (or turn back into place) and re-install the
M4 roll adjustment screws and washers (7). Do not tighten the M4 roll adjustment screws for the roll angle.
1
2
3
4
5
6
7
8
Bracket Mounted
9
Figure 33. Pitch and roll angle adjustment bracket (SXA-MBK-1)
If only pitch adjustment is desired, the entire SXA-MBK-1 can be used with the roll adjustment centered (level) or the back
plates (6 and 8) can be removed and only the pitch adjustment bracket (1) is used to mount the scanner. To remove 6 and 8
first remove the roll adjustment screws (7) to remove the back plate (8). Then remove the four screws that attach (6) to (1)
from the back.
The pitch adjustment plate (1) can now be mounted to the 73 mm spaced holes using the M5 UNI 5933 screws (9). Tighten
the screws, alternating between the two, until they are tight (2.5 to 3 N·m torque).
3.10.4 Mounting the Scanner and Adjusting the Angle
When mounting the brackets or scanner, do not exceed the listed torque or you will damage the scanner. The pitch angle
adjustment procedure applies to both uses of the bracket assemblies.
The Positioning Memory Bracket (one piece) saves the inclination angle set for the installation. This allows for quick
installation without further mechanical adjustments if it is ever necessary to replace the unit.
SX5 Safety Laser Scanner
38
www.bannerengineering.com - Tel: +1.763.544.3164