Figure 1. DF-G2 IO Link Model Features
1. Output LED
2. CH1/CH2 Switch
3. RUN/PRG/ADJ Mode Switch
4. Lever
Action
Fiber Clamp
5. Red Signal Level
6. Green Threshold
7. +/SET/- Rocker
Button
1.3 Top Panel Interface
Opening the dust cover provides access to the top panel interface. The top panel interface consists of the RUN/PRG/ADJ mode switch,
CH1/CH2 switch, +/SET/- rocker
button,
dual red/green digital displays, and output LED.
RUN/PRG/ADJ Mode Switch
The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode.
• RUN mode allows the sensor to operate normally and prevents
unintentional
programming changes via
the +/SET/- rocker
button.
• PRG mode allows the sensor to be programmed through the display-driven programming menu (see
• ADJ mode allows the user to perform Expert TEACH/SET methods and Manual Adjust (see
page 12).
CH1/CH2 Switch (Dual Output Mode)
The CH1/CH2 switch selects which output's parameters can be accessed and changed in the interface of the
display.
+/SET/- Rocker
Button
The +/SET/- rocker
button
is a 3-way
button.
The +/-
positions
are engaged by rocking the
button
left/right.
The SET
position
is engaged by clicking down the
button
while the rocker is in the middle
position.
All three
button
positions
are used during PRG mode to navigate the display-driven programming menu. During ADJ mode, SET is used to
perform TEACH/SET methods and +/- are used to manually adjust the threshold(s). The rocker
button
is disabled
during RUN mode, except when using Window SET.
Red/Green Digital Displays
During RUN and ADJ modes, the Red display shows the signal level, and the Green display shows the threshold or
the total counts. During PRG mode, both displays are used to navigate the display-driven programming menu.
Dual Output LEDs
The output LEDs provide a visible
indication
when the associated output is
active
(conducting).
• 1 represents the Channel 1 output
• 2 represents the Channel 2 output
DF-G2 High Speed Expert Dual Display Fiber
Amplifier
with Dual Discrete Outputs and IO Link
4