Note: TEACH
Selection
must be programmed to CAL SEt.
1. Enter Adjust Mode
Method
Action
Result
SET
Button
20
•
Set Mode switch to ADJ
Display: Red - Signal Level; Green -
Threshold
Remote Input 21
No
action
required; sensor is ready for
Calibration
SET method
2. SET Sensing
Condition
Method
Action
Result
SET
Button
•
Present sensing
condition
•
Click the SET rocker
button
Threshold
Condition
Accepted Displays
read "cAL SEt" then
flashes
"PASS"; Sensor
returns to Adjust mode
Threshold
Condition
Unacceptable
Displays read "cAL SEt" then
flashes
"FAIL";
Sensor returns to Adjust mode
Remote Input
•
Present sensing
condition
•
Single-pulse the remote input
T
3. Return to RUN Mode
Method
Action
Result
SET
Button
Move Mode switch to RUN
Display: Red - Signal Level; Green -
Threshold
Remote Input
No
action
required; sensor returns to RUN
mode
automatically
3.5.2
Troubleshooting
Manual Adjustments Disabled
Manual adjustments are disabled when Auto Thresholds are ON. If a manual adjustment is
attempted
while Auto Thresholds are ON,
the Green display will
flash
.
Percent Minimum
Difference
after
TEACH
The Two-Point and Dynamic TEACH methods will
flash
a % minimum
difference
on the displays
after
a PASS or FAIL.
Value
PASS/FAIL
Description
0 to 99%
FAIL
The
difference
of the taught
conditions
does not meet the required minimum
100 to 300%
PASS
The
difference
of the taught
conditions
just meets/exceeds the required minimum, minor
sensing variables may
affect
sensing reliability
300 to 600%
PASS
The
difference
of the taught
conditions
sufficiently
exceeds the required minimum, minor
sensing variables will not
affect
sensing reliability
600% +
PASS
The
difference
of the taught
conditions
greatly exceeds the required minimum, very stable
operation
20 SET
Button:
0.04 seconds
≤
"Click"
≤
0.8 seconds
21 Remote Input: 0.04 seconds
≤
T
≤
0.8 seconds
DF-G2 High Speed Expert Dual Display Fiber
Amplifier
with Dual Discrete Outputs and IO Link
www.bannerengineering.com - Tel: 763.544.3164