Percent
Offset
after
SET
The Window, Dark, and Light SET methods will
flash
a %
offset
on the displays
after
a PASS or FAIL.
SET Result
%
Offset
Meaning
PASS (with %
Offset)
Displays the %
offset
used for the SET method
FAIL (with %
Offset)
Displays the minimum required %
offset
necessary to PASS the SET method
FAIL (without %
Offset)
Presented
condition
cannot be used for the SET method
Threshold Alert or Threshold Error
Severe
contamination/changes
in the taught
condition
can prevent the Auto Thresholds algorithm from
optimizing
the threshold(s).
State
Display
Description
Corrective
Action
Threshold Alert
Alternates
and
The threshold(s) cannot be
optimized,
but the sensor's output will
still
continue
to
function
Cleaning/correcting
the sensing
environment and/or a re-teach of the sensor
is highly recommended
Threshold Error
The threshold(s) cannot be
optimized,
and the sensor's output will stop
functioning
Cleaning/correcting
the sensing
environment and/or a re-teach of the sensor
is required
DF-G2 High Speed Expert Dual Display Fiber
Amplifier
with Dual Discrete Outputs and IO Link
22