3.2.3 Response Speeds
Description
Response Speed
Repetition
Period
Repeatability
Cross-Talk
Avoidance
Energy
Efficient
Light Resistance
Maximum Range,
Red3
Maximum Range,
IR8504
Fast
50 us
12 us
12 us
No
No
500
750
Standard
250 us
50 us
50 us
Yes
No
725
1300
Medium Range
500 us
80 us
80 us
Yes
No
900
1600
Long Range
1000 us
165 us
165 us
Yes
No
1100
2100
Long Range (with Immunity)
2000 us
165 us
165 us
Yes
Yes
1100
2100
3.2.4
Offset
Percent
The
Offset
Percent is used during the Window, Light, or Dark SET methods. The threshold(s) are
positioned
a programmable %
offset
from the taught
condition.
The allowable
offset
percent range varies based on the response speed, teach method and
sensitivity
settings
as shown below:
Teach Method
Response Speed
Sensitivity
Offset
% Range
Window Set, Light Set
50 µs, 250 µs
High
2 to 98%
Standard
5 to 95%
Low
10 to 90%
500 µs, 1000 µs, 2000 µs
High
1 to 99%
Standard
2 to 98%
Low
5 to 95%
Dark Set
50 µs, 250 µs
High
2 to 999%
Standard
5 to 999%
Low
10 to 999%
500 µs, 1000 µs, 2000 µs
High
1 to 999%
Standard
2 to 999%
Low
5 to 999%
3.2.5 Auto Thresholds
Auto Thresholds can be programmed to be ON/OFF. The Auto Thresholds algorithm
continuously
tracks slow changes in the taught
condition(s),
and
optimizes
the threshold(s) to provide for reliable sensing. For Two-Point and Dynamic TEACH, the algorithm
optimizes
the threshold to be centered between the light and dark
conditions.
For Window, Light, and Dark SET, the algorithm
optimizes
the
threshold(s) to maintain the programmed
Offset
Percent from the taught
condition.
•
After
programming Auto Thresholds to ON, it is highly recommended to re-perform the TEACH/SET method
• Manual Adjustments are disabled when Auto Thresholds are ON
• Auto Thresholds are
automatically
disabled in
Calibration
SET (see
on page 20)
• Severe
contamination/changes
in the taught
condition
can prevent the Auto Thresholds algorithm from
optimizing
the
threshold(s). If this occurs, the DF-G2 enters a Threshold Alert or Threshold Error state. See
on page 21 for
more
explanation.
3 Excess Gain = 1 at High
Sensitivity
setting;
opposed mode sensing using PIT46U
plastic
fiber
4 Excess Gain = 1 at High
Sensitivity
setting;
opposed mode sensing using IT.83.3ST5M6 glass
fiber
DF-G2 High Speed Expert Dual Display Fiber
Amplifier
with Dual Discrete Outputs and IO Link
10