Window SET
• Sets window thresholds that extend a programmable %
offset
above and below the presented
condition
• All other
conditions
(lighter or darker) cause the output to change state
• Sensing window center can be adjusted using "+" and "-" rocker
button
(Manual Adjust)
• Recommended for
applications
where a product may not always appear in the same place, or when other signals may appear
• See Program Mode for programming the
Offset
Percent
setting
A single sensing
condition
is presented, and the sensor
positions
window thresholds a programmable %
offset
above and below the
presented
condition.
In LO mode, Window SET designates a sensing window with the Output ON
condition
inside the window, and the
Output OFF
conditions
outside the window.
Sensor positions
window thresholds
a programmable %
offset from the
presented condition
Darkest
(no signal)
Most Light
(saturated
signal)
Condition
Presented
Sensing Window
Output OFF
Output OFF
Output ON
Figure 10. Window SET (Light Operate shown)
Output ON and OFF
conditions
can be reversed using the LO/DO switch.
Window SET and Manual Adjust
Moves sensing window center value up or down to make adjustments
• Slide Mode switch to ADJ to enter Adjust mode
• Press "+" to increase; press "-" to decrease
◦
GREEN display shows the sensing window center value
◦
2 seconds
after
adjustment, the GREEN display will
flash
3
times
to
confirm
• Slide Mode switch to RUN to complete
operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Window SET:
Note: TEACH
Selection
must be programmed to wind SEt.
1. Enter Adjust Mode
Method
Action
Result
SET
Button
11
Set Mode switch to ADJ
Display: Red - Signal Level; Green -
Threshold
Remote Input 12
No
action
required; sensor is ready for
Window SET method
2. SET Sensing
Condition
11 SET
Button:
0.04 seconds
≤
"Click"
≤
0.8 seconds
12 Remote Input: 0.04 seconds
≤
T
≤
0.8 seconds
DF-G2 High Speed Expert Dual Display Fiber
Amplifier
with Dual Discrete Outputs and IO Link
16
www.bannerengineering.com - Tel: 763.544.3164