![Bang & Olufsen BeoVision 12-65 MK II Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/bang-and-olufsen/beovision-12-65-mk-ii/beovision-12-65-mk-ii_installation-manual_3730928022.webp)
Screen measurement - Measure Screen 22
MEASURE SCREEN - sequence
- Select
MEASURE SCREEN
and press the
Centre
button.
The following is shown:
ROTATE THE DIFFUSER AWAY FROM
THE LENS BEFORE STARTING AND
PLACE SENSOR ON THE GREEN
SQUARE NOT OVERLAPPING THE RED
AREA.
ONCE POSITIONED CORRECTLY YOU
WILL BE ABLE TO PRESS START AND
INITIATE SCREEN MEASUREMENTS.
Ambient light condition
Perform the screen measurements in lighting conditions as dark as possible to minimise the influence of ambient light.
Warm up sequence
- If the BeoVision 12-65 has not been switched
On
for 5 minutes, a warm up sequence is started, indicated by the following text:
A WARM UP SEQUENCE OF 5
MINUTES WILL BE SHOWN BEFORE
STARTING ACTUAL MEASUREMENTS.
In the warm up period, the picture will show coloured pixels. When the warm up period is ended continue on next page.
- If the BeoVision 12-65 has been switched
On
for 5 minutes or more continue on next page.
√
X