5
NOTE:
If a SG200 is used to monitor a starting-only bank using
the cable posts, and not the voltage-only leads, then an accurate
state of health may not be determined or maintained.
The diagram above shows a typical installation with one house battery
bank, and two auxiliary or engine start batteries.
If multiple displays or shunts are being installed, they may simply be
daisy-chained with additional SmartLink communication cables.
Negative leads from auxiliary batteries to the shunt are not needed in a
common-ground installation.
CAUTIONS & WARNING:
DO NOT install any of
the positive leads without proper fusing!!!
NOTE:
The fuse holder is shipped without the fuse
installed. Install the fuse AFTER completely connecting all
of the wires/cables, and all other installation steps.
The SG200 will scale automatically to the voltage of commonly used bat-
tery systems (12v,24v,36v,48v.)
Initial configuration of the SmartShunt consists of setting the following
parameters.
1. Battery Chemistry
2. Battery Capacity
3. Charge Termination Current and Voltage
For complete instructions, follow the rest of this manual.