29
Fault Thresholds
FAULT
Flooded
AGM
TPPL CARFOAM LIFEPO4
GEL
Dual
Purpose
High
Voltage
16.3
15
15
15
14.3
14.4
15
Low
Voltage
10.5
10.5
10.5
10.5
13
10.5
10.5
Low
SoC
5
5
5
5
5
5
5
Low
SoH
20
20
20
20
40
20
20
High
Current
351A (Scales with multiple SmartShunts in Parallel)
Converting Reserve Capacity to Amp Hours
The following formula converts Reserve capacity, typically expressed in min-
utes drawing a 25 amp load, to Amp hours at the 20/HR rate.
RC(60)*25/3600
Multiply Reserve Capacity to 60 to convert to seconds
Multiply by 25 to convert to coulombs
Divide by 3600 to convert coulombs to amp/hours
Example:
We have a battery showing reserve minutes of 130
130*60 = 7800
7800 * 25 = 195,000
195,000/ 3600 = 54.16
We have a battery showing reserve minutes of 130
130*60 = 7800
7800 * 25 = 195,000
195,000/ 3600 = 54.16