26
The values used to trigger Faults are contained in the Appendix named Fault
Thresholds
Fault History is accessed from within the History Sub-menu, see History.
NOTE:
The High Voltage Fault threshold for flooded batteries may be
higher than a safe voltage for operating electronics and other equipment.
This is to allow for the equalization of batteries without triggering a Fault.
For this reason, it is important to set and use a High Voltage Alert to let
the user know when potentially battery-damaging voltages are sensed.
Comparing Faults and Alerts
Here is a summary of some differences between Faults and Alerts:
1. Alerts are user-configurable; you can enable and disable alerts and change
their trigger points.
2. When an alert condition has passed, the alert does as well.
3. Faults are not user configurable.
4. Faults show a time since occurred, duration for the latest fault, and the
number of total times that fault has occurred.
5. Faults have history. When a fault is viewed, it is cleared from the screen.
The parameters for the last instance of a fault and a counter showing the
total times that fault occurred are stored.