Advanced Settings
The advanced menu for any SmartShunt allows the user to perform
several levels of reset of SmartLInk devices on the network. An
explanation of each of options is in the table below:
Menu Option
Description
RESTART DEV
RESTART DEVICE - Reboots the device (a Display
or SmartShunt) that is currently selected (Shown
at the top of the screen).
RESET
NETWORK
RESET NETWORK - Resets the SmartLink
network. Learning, chemistry, faults etc are
retained.
FACTORY RST
FACTORY RESET - Performs a FULL reset of the
device. ALL history, including faults, chemistry,
capacity, learning etc is reset. Performing a
Factory reset on device, does not perform a reset
on any other devices or SmartShunts on the
network. A Factory Reset should be performed
every time a battery bank is replaced.
Performing a long press on any of the advanced settings immediately
performs that function, except for FACTORY RESET, which has a
confirmation step to help avoid false resets.