www.balluff.com
17
english
6.3
Parameter data
6.3.1 Identification data
Tab. 6-3: Identification data
R:
Read-only
R/W:
Read and write access
*:
The application tag can be defined by the user.
Product name
Product ID
Device ID
BLA 100D-002-S4
BLA000J
721157
BLA 72D-002-S4
BLA000F
721155
BLA 50D-002-S4
BLA000C
721156
BLA 32D-002-S4
BLA0009
721154
Tab. 6-4: Product and device ID
6.3.2 System commands
Under the index 0x02 (length 1 byte), the system com-
mands for executing the corresponding functions are
available under the values listed below:
Value
Function
0x80
Restart device
0x81
Restart application
0x82
Restore factory settings
0xA0
Signal normalization
0xA5
Reset maintenance interval
0xAF
Device discovery
Tab. 6-5: System commands
6.1 IO-Link-Data
The switching frequency of the device is mainly determined
by the transmission speed of the IO-Link interface.
The characteristic parameters of the interface are:
Data transfer rate
COM2 (38.4 kBaud)
Minimum cycle time
BLA32D 5.0 ms
BLA50D 5.4 ms
BLA72D 6.2 ms
BLA100D 8.0 ms
Process data length
10 Byte PDI
IO-Link Revision
1.1
1.0
Frame type
2.V
1.2 / 1.1
Tab. 6-1: IO-Link data
6.2 Process data
For continuous data transmission, 10 bytes of process
data (PDI) are transmitted:
No.
variable
Length
(bit)
Type
Content
1
32
IntergerT
Analog output value 1
2
32
IntergerT
Analog output value 2
3
8
UIntergerT
Object output value
4
8
Bitmaske
Bit 5
Signal normalization
active
Bit 6
Autoblanking
active
Bit 7
Full coverage
Tab. 6-2: Process data
The analog output values are in µm, the value range here is
from 0 to the length of the active measuring range of the
sensor.
The object output value depends on the activated functions:
In object detection mode, the taught number of the detec-
ted object is output (0: no object; 1-6: detected objects; 7:
unknown object). If simultaneous counting of objects is
activated, the number of detected objects is output.
Several status messages are output simultaneously in vari-
able no. 4:
Bit 5 indicates whether the BLA is currently performing signal
normalisation. Bit 6 indicates whether autoblanking was acti-
vated during the last signal normalization. In case no light arri-
ves at the receiver, bit 7 is set to 1. This allows a completely
covered light band to be detected.
DPP
Index
Object name
Length
(Byte)
Access
Default value
0x07
0x08
Vendor ID
2
R
888 (0x0378)
0x09
0x0A
0x0B
Device ID
3
R
Index Object name
Length
(Byte)
Access
Default value
0x10
Vendor
name
7
R
"BALLUFF"
0x11
Vendor text
15
R
"www.balluff.com"
0x12
Product
designation
48
R
0x13
Product ID
7
R
0x14
Product text
64
R
"Balluff Light Array"
0x15
Serial number 16
R
0x16
Hardware
revision
10
R
0x17
Firmware
revision
10
R
Vx.xx
0x18
Application
tag*
32
R/W
6
IO-Link interface
BLA Series D
Balluff Light Array
Содержание IO-Link BLA D Series
Страница 2: ...www balluff com...