www.balluff.com
7
english
Fig. 3-2: Holder dimensions for emitters BLA 72D und BLA 100D
3.2
Electrical connections
Connect the emitter and receiver using a 4-conductor
cable (all conductors through-connected 1:1). The emitter
has an M12 male plug and the receiver an M12 female.
A M12 male plug is used for power supply and data
output.
Standard
IO-Link
Pin Strand
colour
Function
Pin Strand
colour
Function
1
white
Digital output 1
1
brown
+Ub
(18…30 V)
2
brown +Ub
(18…30 V)
2
white
not used
3
green
Analog output 1
(0-10 V or 4-20 mA)
3
blue
Ground 0 V
4
yellow Digital output 2
4
black
IO-Link
5
grey
Analog output 2
(0-10 V or 4-20 mA)
6
pink
Digital output 3
7
blue
Ground 0 V
8
red
Analog Ground
Tab. 3-1: Pin assignment
3.1
Installation
Mounting instructions
– Install the devices solidly on a stable, vibration-free
holder.
– Be sure that the orientation of the devices cannot
change during startup or in normal operation.
Especially the emitter and receiver must not be
permitted to move relative to each other, since
otherwise incorrect measurements and failed object
detection can result.
– Locate the devices where they are protected against
the accumulation of dust, dirt or liquids.
– Do not install the devices in a location where they are
exposed to direct sunlight or strong ambient light,
since excessive ambient light can result in faulty
measurements.
The device can be installed horizontally or vertically.
Fastening options:
Custom fastening system
Two M4 screws are used for fastening. Use either two of
the three through holes on the top side or the two threa-
ded holes on the side.
Mounting brackets from Balluff
The supplied stainless steel mounting brackets allow
flexible positioning and easy alignment of emitter and
receiver by slotted holes.
Fig. 3-1: Holder dimensions for all receivers and emitters