www.balluff.com
15
english
5
Display and menu
Analog output 1
Selected mode
Analog output 1
Current measurement value [mm]
Status LED 2
Object indicator
Status LED 1
Power indicator
Analog output 2
Current measurement value [mm]
Analog output 2
Selected mode
Hidden area
Blanking function active
Visualization of the
object in the light band
Number of the
detected object
Object output value
Selected mode
Fig. 5-1: Image of user interface with current measurement values
Area automatically hidden
during normalize (Autoblanking)
5.1
Control panel
After the unit is powered up, it is ready to use and displays
the current measurement values together with the selected
measuring modes.
The unit is controlled using 4 keys on the BLA receiver:
Label
Function
˄
Page forward in the list
Increase values
˅
Page back in the list
Decrease values
•
Confirm
c
Go back to the higher menu level
Tab. 5-1: Function of the keys
Fig. 5.1 shows the operating elements and the display of the
BLA with the measured value display. All displayed informa-
tion is explained there.
Status LED meanings:
LED 1 (green): Device is switched on / flashing : IO-Link is
active.
LED 2 (orange): Device is on when there is an object in the
light band (at least one edge detected).
BLA Series D
Balluff Light Array
Содержание IO-Link BLA D Series
Страница 2: ...www balluff com...
Страница 47: ......