BVS ID-M1280xF1-xx-xxx
english
121
Statistics Data Output: Minimum
Minimum value of the measured values over a certain time period.
Statistics Data Output: Maximum
Maximum value of the measured values over a certain time period.
Statistics Data Output: Average
Average of the measured values over a certain time period.
Statistics Data Output: Moving Average
The moving average is an average that is calculated repeatedly over a certain value of the moving average
window.
Statistics Data Configuration: Number of Samples
Total number of read measurement values during start and stop operation of the minimum value/maximum
value/average function.
Statistics Data Output: Status
Bit position
Meaning
Description
0
Configured
1 – all inputs are configured
1
Started Min/Max/Avg
1 – Min/Max/Avg running
2
Started Moving Average
1 – Moving Average running
3
Buffer Overflow Event
1 – buffer overflow
4
Timeout Event
1 – the set time for the minimum value/maximum value/average calculation has
elapsed
5
Reserved
-
6
Reserved
-
7
Reserved
-
System Commands
Command Value
Device Action
0xA7 (167)
Statistics Reset – Resets all output parameters to 0 and all user settings to the default values.
0xA8 (168)
Statistics Start Min/Max/Avg – Starts the statistics of the minimum value/maximum value/average
calculation.
0xA9 (169)
Statistics Stop – Stops statistics operation completely.
0xAC (172)
Statistics Start Moving Average – Starts the statistics of the moving average calculation.
Содержание BVS ID-M1280 F1 Series
Страница 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Страница 2: ...www balluff com...
Страница 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Страница 4: ...www balluff com...
Страница 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Страница 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Страница 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Страница 158: ......
Страница 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Страница 160: ...www balluff com...
Страница 197: ...BVS ID M1280xF1 xx xxx english 39...
Страница 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Страница 315: ...956115_AB EN E23 Subject to modification Replaces K22...