BVS ID-M1280xF1-xx-xxx
86
english
•
•
•
•
•
•
•
•
•
4.3.3.2 Description of the individual signals
Bit String
Bit number
Name
Functional description
0
Not used
1
Job Start
New Transfer job ist started.
2
Job End
0: No job present.
1: The job was finished without errors.
3
Job Error
0: Job finished without error.
1: Job processed incorrectly or aborted.
4
Not used
5
TO
A state change during a job indicates that the BVS ID is ready to transmit further data.
6
Not used
7
Not used
Status Byte
Bit number
Name
Functional description
0
Waiting for
Trigger
The BVS ID is ready for an trigger to acquire an image.
1
Result Data
Available
Inspection result ready to be fetched from the PLC.
2
3
Simulation Mode
"File Device" is selected as image source. The simulation ("File Device") is used to display stored
images.
4
-
5
Ready
The BVS ID works normally and can receive and execute commands. The following actions reset this
bit:
Product start process
Loading process of an inspection program
BVS ID is in configuration mode
Auto setup process
During analysis of saved images
System Error
6
-
7
Device Locked
The BVS ID bit is associated with a controller in active mode. The following actions reset this bit:
PLC terminates its connection.
User logs in as
expert
or
admin
on the client.
User management is deactivated.
NOTE
It is not guaranteed, that the
Waiting for Trigger
bit is reset upon a trigger. After a trigger has been
received, an image is acquired; after this acquisition the
BVS ID
might however be ready for a second
image acquisition so quickly that the bit is never reset. The behavior may vary from trigger to trigger
and is not deterministic in this respect. It is however guaranteed, that a trigger leads to a succesful
image acquisition (instead of an over trigger) if this bit was set while triggering. This bit should
accordingly be used only with respect to its status not with respect to its edge.
Содержание BVS ID-M1280 F1 Series
Страница 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Страница 2: ...www balluff com...
Страница 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Страница 4: ...www balluff com...
Страница 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Страница 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Страница 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Страница 158: ......
Страница 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Страница 160: ...www balluff com...
Страница 197: ...BVS ID M1280xF1 xx xxx english 39...
Страница 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Страница 315: ...956115_AB EN E23 Subject to modification Replaces K22...