Parameters
Description
Data type
Image source
Selection of an image source. The simulation ("Image files") can be used to display and
process stored images.
Trigger mode
Continuous - no external triggering active. The sensor captures image in free-run
mode.
Rising edge - acquires images, if a low->high transition takes place on the input.
Flash source
None - flash is not active
White LEDs - white internal LEDs are used.
Red/infrared LEDs (according to the model) - red / infrared internal LEDs are used.
External lightning - an external flash is used.
External lightning with boost - an external flash is used, and an additional line
(boost) is activated.
Exposure time [ms]
Shutter speed of the image sensor in milliseconds (0.01 to 1000 ms)
Double
Gain factor [dB]
Controls the gain as an absolute physical value in dB.
This is an amplification factor that is applied to the image signal. However, this increases the
noise of the image signal.
Double
Working distance [mm]
Specifies the focus distance (distance between sensor front and code to be read) for a
sharp image (
50 - 600 mm).
Int
Width [pixel]
1
Width of the image area (AOI; minimal 16 Pixel, maximal
1280
Pixel)
Int
Height [pixel]
1
Height of the image area (AOI; minimal 16 Pixel, maximal
960
Pixel)
Int
Position X [pixel]
1
Horizontal start position of the image area (AOI)
Int
Position Y [pixel]
1
Vertical start position of the image area (AOI)
Int
1
By default, the
BVS ID
uses the full image field when searching for the code to be read. To speed up the
reading process or to make it more robust, the search field can be reduced by using an image area.
NOTE
Trigger signals are discarded as soon as no image can be captured internally.
In this case, a "Trigger Overflow" signal is generated in the product status.
NOTE
This value is automatically set during the auto setup process.
NOTE
This value should be set at normal ambient temperature and with the device at
operating temperature.
NOTE
This value is automatically set during the auto setup process.
NOTE
The millimeters displayed here are not exact. Depending on the prevailing
wavelength of the light, this value can deviate, e.g. when using external infrared
lighting. It is recommended to have this setting set automatically using the auto
setup process, or to focus the image by sight. It is not recommended to
determine this value by measuring distances or using CAD data.
Содержание BVS ID-M1280 F1 Series
Страница 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Страница 2: ...www balluff com...
Страница 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Страница 4: ...www balluff com...
Страница 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Страница 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Страница 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Страница 158: ......
Страница 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Страница 160: ...www balluff com...
Страница 197: ...BVS ID M1280xF1 xx xxx english 39...
Страница 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Страница 315: ...956115_AB EN E23 Subject to modification Replaces K22...