
BVS ID-M1280xF1-xx-xxx
84
english
4.3.3 Process data
The data exchange takes place via the process data, which are mapped in the input and output buffer, or in a
memory field, depending on the control system used. 32 bytes of input data and 32 bytes of output data
including bit strips are used. The assignment is described below. The sub address 0x00 corresponds to the
start address in the corresponding data field.
To transfer commands and data between the
BVS ID
and the controlling system (PLC) the
BVS ID
provides
two fields input and output buffer.
The signaling via the bit strip is currently transmitted in each PLC cycle. Hereby the PLC recognizes at any time
the status of the
BVS ID
and can also send control signals to the
BVS ID
at any time. These fields are
embedded in the process data transmission via the IO-Link master.
NOTE
In the Comprehensive Condition Monitoring (CCM) variant, the 31st byte of the
BVS ID
is filled with the
CCM byte. This means that only 29 bytes are available for transferring the input buffer of process data
and the 2nd bit string is transferred at byte n+30.
Содержание BVS ID-M1280 F1 Series
Страница 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Страница 2: ...www balluff com...
Страница 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Страница 4: ...www balluff com...
Страница 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Страница 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Страница 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Страница 158: ......
Страница 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Страница 160: ...www balluff com...
Страница 197: ...BVS ID M1280xF1 xx xxx english 39...
Страница 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Страница 315: ...956115_AB EN E23 Subject to modification Replaces K22...