59
deutsch
59
E
4 diagnostic LEDs on the motherboard inside the processor report the key operating states
on the I
NTER
B
US
.
LED
State
I
NTER
B
US
message
UL
green / off
Reset
Protocol chip is / is not supplied
with power.
RC / CC
green / off
Communication Ready
Remotebus Check
Communication with the IBS-
Cable Check
Master is / is not possible, the
application has not however yet
started to exchange data.
BA
green / off
Communication active or also Run
Bus Active
Master is / is not exchanging user
data.
RD
yellow / off Remotebus Disable
Remotebus Disable
The extended bus interface is / is not
turned off.
Operating state
I
NTER
B
US
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
X5
Head 1
Head 2
UL
CC
BA
RD
Function displays
C60_1-023_819395_0508_en.p65
60
60
E
Mounting the
read/write head or
adapter
BIS C-6001
Mounting Head / Processor
Depending on model, the processor is equipped with a read/write head or the adapter for
offset read/write heads. Both the read/write head and the adapter can be rotated by the user
by + or -90° to the desired
position (see drawing). Be sure
that power is off first. Loosen
both screws (indicated with
arrows). Carefully pull the head
or adapter out towards the
side (direction of arrow, right
drawing).
Caution: wires inside!
Reattach at the desired
orientation and screw tight
again.
The processor is attached
using 4 lateral mounting holes.
Caution:
wires inside!
Mounting the
BIS C-6001
processor