5
deutsch
5
E
Principles
This manual is designed to assist the user in setting up the control program and installing and
starting up the components of the BIS C-60_1 Identification System, and to assure rapid,
trouble-free operation.
The BIS C Identification System belongs in the category of
non-contact systems for reading and writing.
This dual function permits applications for not only transporting information in fixed-programmed
data carriers, but also for gathering and passing along up-to-date information as well.
If 2 read/write heads are connected to a BIS C-60_1 processor, both heads can be operated
independently of each other. This means for example that you can read a data carrier from one
head while writing to another data carrier at the other head.
Some of the notable areas of application include
– for controlling material flow in production processes
(e.g. in model-specific processes),
for workpiece conveying in transfer lines,
in data gathering for quality assurance ,
for gathering safety-related data,
– in tool coding and monitoring;
– in equipment organization;
– in storage systems for monitoring inventory movement;
– in transporting and conveying systems;
– in waste management for quantity-based fee assessment.
Introduction
BIS C Identification System
Applications
☞
C60_1-023_819395_0508_en.p65
6
6
E
System Components
Introduction
BIS C Identification System
Processor
with Read/
Write Head
Processor
with
Adapter
I
NTER
B
US
(remote bus)
Data carriers BIS C-1_ _-...
Read/Write
Heads
1)
Schematic
representation of an
Identification System
(example)
1
) BIS C-3_ _ series, except BIS C-350 and -352
2
) BIS C-350 or -352 only
BIS C-6001
BIS C-6001
Read/Write
Head
2)
Processor
with
Adapter
BIS C-6001
The main components of the BIS C Identification System are
–
Processor,
–
Read/Write Heads and
–
Data carriers
.
Configuration with
BIS C-6001
processor