www.balluff.com
58
8.11
CAM-configu ration
This section gives an example how to configure the cam-channel:
That means for single cams:
CAM
Angular area
lower CAM-limit
upper CAM-limit
Hysteresis
1
0°..180°
0
2048
0
2
180°..360°
2049
4095
0
3
0°..60°
0
682
0
Table 8.67: Example CAM-configuration
•
The configuration must be done in Pre-Operational state.
To enable the individual cams the CAM-enable-register (object 6301h-01h) is used. For example the setting
00000111b = 07h enables the first three cams.
600h+ID
8
23h
01h
63h
01h
07h
00h
00h
00h
CAN-ID
DLC Command
Object L Object H Sub-
Index
Byte0
Byte1
Byte2
Byte3
Table 8.68: Enable first three cams
Now the cam-high-limits 1, 2, and 3 can be set as in the table above:
CAM 1 = 2048 = 0800h
600h+ID
8
23h
20h
63h
01h
00h
08h
00h
00h
CAN-ID
DLC Command
Object L Object H Sub-
Index
Byte0
Byte1
Byte2
Byte3
Table 8.69: CAM-High-Limit 1
CAM1 0°=>180°
CAM2 180°=>360°
CAM3 0°=> 60°