7-16 Parameter Descriptions
MN762S
7.4 Advanced Parameters
The VS1MXS contains advanced parameters described in this section. These parameters are not
visible to end users unless P1-14 is set to a value of ‘702’. The parameters are list below.
7.4.1 Advanced Parameters
Table 7-6 Advanced Parameters - Parameter Group 5
Par
No.
Description
Range
Units
Default
Explanation
P5-01
Motor Stator
Resistance (Rs)
Drive
dependent
Ω
-
During an auto tune, the drive
measures / calculates these
parameters to optimize the motor
control performance. The values
can be adjusted by the user,
however this may have a negative
effect on the motor behavior, or
cause unexpected results, and
this is not recommended.
P5-02
Motor Rotor
Resistance (Rr)
Drive
dependent
Ω
-
When set to 1, the drive
immediately carries out a non-
rotating auto tune to measure the
motor parameters for optimum
control and efficiency.
P5-03
Stator Inductance
(Ls)
Drive
dependent
-
-
P5-04
Magnetizing
Current
(Id rms)
10% to 80%
of motor rated
current
A
-
P5-05
Leakage
Coefficient (sigma)
0.025 to 0.250
-
-
P5-06
Reserved
-
-