Installing the Drive 3-1
MN762S
Chapter 3
Installing the Drive
This chapter provides information that must be considered when planning a VS1MXS drive installation
and provides drive mounting information and installation site requirements.
3.1 Receiving & Inspection
When you receive your control, there are several things you should do immediately.
1. Observe the condition of the shipping container and report any damage immediately to the
commercial carrier that delivered your control.
2. Remove the control from the shipping container and remove all packing materials from the
control. The container and packing materials may be retained for future shipment.
3. Verify that the part number of the control you received is the same as the part number listed on
your purchase order.
4. Inspect the control for external physical damage that may have been sustained during shipment
and report any damage immediately to the commercial carrier that delivered your control.
5. If the control is to be stored for several weeks before use, make sure that it is stored in a location
that conforms to published storage humidity and temperature specifications stated in this manual.
3.2 General Requirements for the Installation Site
It is important to ensure that the drive’s environment and operating conditions are satisfactory. The
area behind the drive must be kept clear of all control and power wiring. Power connections may
create electromagnetic fields that may interfere with control wiring or components when run in close
proximity to the drive. Read the recommendations in the following sections before continuing with the
drive installation.
3.2.1 Operating Conditions
•
Operating surrounding temperature must be within 32°F (0°C) to 104°F (40°C).
If surrounding temperature exceeds 40°C, de-rate the output by 5% per °C above 40°C up to 55°C
maximum surrounding temperature.
•
Protect the cooling fan by avoiding dust or metallic particles.
•
Do not expose the drive to a corrosive atmosphere.
•
Protect the drive from moisture and direct sunlight.
•
Verify that the drive location will meet the environmental conditions specified in Table 3-1.
3.2.2 Minimum Mounting Clearances
Be sure to provide proper top and bottom clearance 5.9 inches (150mm) for cooling.
Side to side clearance is minimal and controls can be almost touching.
Table 3-1 Surrounding Temperatures and Mounting Clearances
Surrounding Temperature
Enclosure Rating
Minimum Mounting Clearances
(Vertical)
Minimum
Maximum
32°F (0°C)
104°F (40°)
NEMA 12 / IP55
5.9 in (150mm)
Содержание VS1MXS51
Страница 1: ...03 11 Installation Operating Manual MN762S VS1MXS AC Extreme Duty Microdrive...
Страница 28: ...5 10 Control Wiring MN762S...
Страница 58: ...7 24 Parameter Descriptions MN762S...
Страница 60: ...8 2 Customizing Your Application MN762S...
Страница 80: ...D 2 Options and Kits MN762S...
Страница 85: ......
Страница 86: ......