5-2 Control Wiring
MN762S
5.2 RJ11 Communication Connection
The RJ11 Data Port can be used as a RS485 Serial interface using Modbus RTU protocol.
Serial Modbus networks use the RS485 PIN connection; see Appendix E for the communication
protocols.
Figure 5-2 RJ11 Data Connection
RS485
0 Volts
+24 Volts
Optibus -
O
RS485 Modbus -
Table 5-2
Protocol
Modbus RTU
Error check
CRC
Baud rate
9600bps, 19200bps, 38400bps, 57600bps, 115200bps (default)
Data format
1 start bit, 8 data bits, 1 stop bits, no parity
Physical signal
RS485 (2-wire)