Parameter Descriptions
7-11
P43
Preset Speed 1
P44
Preset Speed 2
P45
Preset Speed 3
Range:
0 - 400 [Hz]
Default:
P43 = 10, P44 = 20, P45 = 30
Access
Tunable
See Also:
t1-t8, t10-t13
Provides an internal fixed speed command selectable by digital inputs.
P46
Drive Start/Stop Source 2
Range:
0 - 3 (see table for P38)
Default:
1 = Terminal Mode 1
Access
Configurable
See Also:
P38, t1-t8
Note:
Only viewable when one of the t1-t8 terminals is set
for 22 and P38 = 3 (RS485 Communications).
When RS485 communications is used as the primary mode of controlling
the drive, this parameter serves as an alternate mode. It is selectable by a
digital input (t1-t8) = “22”.
P47
Frequency Setting Mode 2
Range:
1-7 (see table for P40)
Default:
1 = Keypad
Access
Configurable
See Also:
P40, P47, t1-t8
Note:
Only viewable when one of the t1-t8 terminals is set
for 22 and P40 = 7 (RS485 Communications).
When RS485 communications is used as the primary mode of controlling
the drive, this parameter serves as an alternate mode. It is selectable by a
digital input (t1-t8) = “22”.
Содержание VS1MD
Страница 2: ...Instruction Manual VS1MD User Manual MN760 3 6 07...
Страница 5: ...4 VS1MD AC Drive User Manual...
Страница 11: ...1 2 VS1MD AC Drive User Manual...
Страница 27: ...4 8 VS1MD AC Drive User Manual...
Страница 103: ...7 58 VS1MD AC Drive User Manual...
Страница 131: ...8 28 VS1 MD AC Drive User Manual 8 13 Control Block Diagram m G k G h Vk Vm w t t...
Страница 133: ...8 30 VS1 MD AC Drive User Manual...
Страница 143: ...9 10 VS1 MD AC Drive User Manual...
Страница 150: ...Options Kits B 5 B 2 4 VS1MD NM1C B 2 5 VS1MD NM1D...
Страница 155: ...B 10 VS1MD User Manual...
Страница 167: ...VS1MD User Manual...
Страница 168: ......
Страница 169: ...Publication MN760 3 2007 Baldor Electric Company All rights reserved...