On the first days of
CRI
work, check the oil level of the bearings daily, then check every
120 hours of work.
The amount of grease in each bearing is 300 grams.
Only use the following grease: EP (Specification DIN51825 KP00K Consistency NLGI 2/3).
Change the oil every 1200 hours of work using 0.270 liters.
Use transmission oil: 90 API GL4, MIL-L-2105; SAEJ306, May/81: SAE 80W, 90 and 140.
Grease bearings must be lubricated every 12 working hours, using the grease specified
below.
The ideal oil level is when it reaches
the plug hole.
To check bearing oil level, search for
a flat surface.
Before lubricating bearings, wipe
grease with a clean, lint-free
cloth. Replace damaged grease
fittings.