Copyright 2011 Baker Hughes Company.
English–DPS 8000 Instruction Manual | 23
Communication Segment
Several parameter groups are distinguished.
For restoring the signature “load” (0x64616f6c) must be written.
OBJECT DESCRIPTION
INDEX
1011
Name
Restore Default Parameters
Object Code
Array
Data Type
UNSIGNED32
ENTRY DESCRIPTION
Sub-Index
000
Description
Number of Entries
Access
RO
PDO Mapping
No
Default Value
0x1
Sub-Index
001
Description
Restore all Default Parameters
Data Type
UNSIGNED32
Access
RW
PDO Mapping
No
Default Value
0x0
A.1.11 Object 1012h: COB-ID Time Stamp
COB-ID of the Time Stamp Object (TIME). If bit
31 is set the device consumes the Time Stamp
message and if bit
30 is set the device produces the Time Stamp message. The meaning of the
other bits is equal to the other communication objects.
OBJECT DESCRIPTION
INDEX
1012
Name
COB-ID Time Stamp
Object Code
Variable
Data Type
UNSIGNED32
ENTRY DESCRIPTION
Access
RO
PDO Mapping
No
Default Value
0x0100
Sub-Index
Parameter Group
1
All parameters.
2
Communication parameters.
3
Application parameters.
4 to 127
Manufacturer defined parameters.
Содержание Druck DPS 8000 Series
Страница 1: ...Druck com DPS 8000 Series CAN bus Pressure Transducer Instruction Manual ...
Страница 2: ......
Страница 6: ...Copyright 2011 Baker Hughes Company iv DPS 8000 Instruction Manual English ...
Страница 10: ...Copyright 2011 Baker Hughes Company viii DPS 8000 Instruction Manual English ...
Страница 28: ...Copyright 2011 Baker Hughes Company 18 DPS 8000 Instruction Manual English ...
Страница 62: ...Copyright 2011 Baker Hughes Company 52 DPS 8000 Instruction Manual English Appendix C Bibliography ...
Страница 63: ......