INTRODUCTION
OPTIONS AND ACCESSORIES
WBPEEUI110505A0
1 - 11
EZ CAL option
1
External nonintrusive device for zero and span validation. Add on
kit no. 258562_1.
Liquid crystal display
option
1
Two-line seven-character display for local output indication. Displays output in
percent and user-defined secondary engineering units, input in primary engi-
neering units, cell temperature, and transmitter ID tag. Mounts in four orienta-
tions for easy viewing. Refer to Table
for the temperature limitations. Add on
kit no. 258550_1 (aluminum cover) or 258550_5 (stainless steel cover).
Analog meter option
1
Provides local output indication for those applications where the transmitter
operates outside the temperature limits of the LCD. Linear 0 to 100 and square
root 0 to 10 graduations on same scale. Add on kit no. 258550_2 (aluminum
cover) or 258550_6 (stainless steel cover).
Process adapter (football
style)
½-NPT stainless steel 316 or Hastelloy C-276 (low pressure side only).
Tantalum diaphragm
For use with highly corrosive fluids.
Lightning arrestor option
1
Mounts internally to suppress lightning induced transients. Tested to suppress
10 successive 8 by 20 µsec pulses with a peak value of 20 kA (reference
IEEE C62.41).
Antistatic kit
Contains static-dissipative work surface (mat), ground cord assembly, wrist
bands, and alligator clip for personnel working on devices containing semicon-
ductor components. Kit no. 1948385_1.
Available drawings
B8113038
Board level wiring diagram.
D3055063
Dimension drawing.
D3055064
Dimension drawing for optional indicator.
D3055065
User field connections.
Configuration option
1
.
.
The transmitters are delivered with a standard configuration. Custom configura-
tions can be ordered by selecting that option in nomenclature position 15. The
factory programmed configuration is listed below, as well as a column to aid in
ordering custom configurations.
NOTE:
1. These items are selected via nomenclature in Table
1-2
.
Table 1-5. Options and Accessories
(continued)
Item
Description
Parameter
Standard Configuration
Custom Configuration
ID tag
PTS
Operating mode
Analog
Output function
Linear - normal acting
Damping
0.5 sec
Engineering units (EU)
in. H
2
O/psi
Lower range value (LRV)
0.0
Upper range value (URV)
URL of transmitter
Initialize output
Low
Fail output
Low
Secondary EU
..MA
Secondary LRL
4.00
Secondary URL
20.00
Cell temp. low alarm
-40°C
Cell temp. high alarm
85°C