When the update process completes, green checkmarks appear in the boxes next to steps 1, 2, 3 and 4 .
18 . Press
Lock
Step 5: Lock System (Reboot), remove the USB drive and press
OK
to reboot .
OTEE:
N
If the thumb drive is not removed before you press
OK
, the unit may lock-up . The error message “Lock EWF Fail” may
also appear in the text area . Remove the thumb drive . When the meter returns to the screen with the grayed-out
Software Update
button, press
Start Flow Meter
to resume normal operations .
See the last page for additional instruction on clearing a lock-up . When the thumb drive is removed the device may continue
on to a system reboot but hang at the Dynasonics splash screen .
This condition requires a hard reboot . Press and hold the main power button until the unit turns off . Press the power button
again to start the meter .