background image

TROUBLESHOOTING DIAGRAM 

 

YES

NO

Display

lit & ok?

NO

CONTACT
FACTORY

Turn power

off, then

back on

Ok

Now?

Turn power off,

unplug display &

plug it back in.

Turn power back on.

Ok

Now

?

NO

YES

YES

Reprogram

for proper flow

& totalizer units

Did unit

program

ok?

Try programming

again. If unit will

not accept changes,

contact factory

Check connector & label

coming from motor on

servo board to recorder

circuit board.  Make sure

all connector pins are

properly mated on correct

motor output.

Also check for mechanical

binding of belt, motor and

pen.  Make sure that pen
arm transport tie down is

removed from unit.

Increase

damping.
See IOM

page 10.

Ok

Now?

CONTACT
FACTORY

Will

pen arm

move with

input now?

CONTACT

FACTORY

YES

GO TO NEXT PAGE

Do

pen arm &

display agree

with input?

Supply known input

value & compare with

display & pen position.

Recapture pen

arm zero & span.

See IOM pg 11.

Does the

display / pen

jump or jerk?

START

ARE THE PEN

ARM, FLOW

DISPLAY &

TOTALIZER

OK?

NO

Display

show legible

characters?

Flow &

total

units

ok?

Pen arm
moves?

Do

pen arm &

display agree

with input?

YES

YES

YES

YES

NO

NO

NO

NO

YES

NO

NO

YES

YES

Recapture pen arm

zero & pen arm span.

See IOM pg 11.

Will

pen arm

move with

input?

YES

YES

NO

YES

NO

NO

NO

YES

NO

TO NEXT PAGE

Check 117 VAC &

connections, power

switch, & fuse

Display

lit & ok?

 

20

 

Содержание 3000+

Страница 1: ...ng Diagram 20 UNPACKING INSPECTION To avoid damage in transit Eastech Badger products are shipped to the customer in special shipping containers Upon receipt of the product perform the following unpac...

Страница 2: ...or pressure or temperature totalization alarm indication and is used to program the recorder through menu driven prompts RECORDING 12 inch circular chart with 24 hour 7 day or 31 day selectable chart...

Страница 3: ...a window The door is provided with two lockable latches Caution should be used when mounting the enclosure so that it is not exposed to direct sunlight A sun shield is recommended to prevent the temp...

Страница 4: ...e dimensions If the outdoor enclosure has the window option do not mount facing the sun or install a sun shade to prevent overheatingoftheelectronicsinsidetheenclosure WIRING CONNECTIONS 4 20 MA OUTPU...

Страница 5: ...en the screws on the connectors Strip off about 1 4 inch of insulation from the wires Insert the wire into the proper connector and tighten the screw securely After connecting all of the wires to the...

Страница 6: ...ow not differential DC power must be connected in series with the load as shown above DRY CONTACT RELAYS MAX LOAD 250 MA 4 20 MA OUTPUT NO C SW 1 NC NO C SW 2 NC 1 2 3 4 5 6 7 8 TB5 RELAY OUTPUTS Rela...

Страница 7: ...reen informs the user of the Model of the recorder This screen will be displayed for a few seconds The next screen to be displayed is the following SOFTWARE REVISION X XX SERIAL NUMBER 12345678 This s...

Страница 8: ...tion of this manual CHT This indicates that the chart has made a complete rotation and the chart needs to be changed INT Indicates a contact integrator pulse output has occurred EE EEPROM read write e...

Страница 9: ...t the following screen will appear MEASUREMENTS UNITS UNIT INITIALS GPM This screen allows the user to select the engineering unit of measure for the flow rate To change the units press the UP or DOWN...

Страница 10: ...1 55 POWER 1 58 POWER 1 95 POWER 1 2 POWER 3 2 POWER 5 2 POWER OPTION The linear function is used where the transmitter output is proportional to flow The 1 55 power is used with 1 2 3 24 Parshall flu...

Страница 11: ...to be at the span value if the UP or DOWN arrow keys are not pressed When pressing the UP or DOWN arrow keys the display will indicate the direction of the pen movement Once the pen is positioned to s...

Страница 12: ...the channels to be summed must be input to the recorder when making this adjustment For example if the input signal is 4 20 mA for 0 to 100 then 4 mA must be input to all channels to be summed to mak...

Страница 13: ...t points If the High alarm is set for 60 percent and the hysteresis is 3 percent then the High alarm will trip closed at 63 percent and open at 57 percent Press the UP or DOWN arrow keys to the desire...

Страница 14: ...or DOWN arrow keys to select YES or NO and press the ENTER key The following screen will appear UNIT MULTIPLIER AAA X 1 000 This screen allows the selection of the desired flow rate multiplier Press...

Страница 15: ...reens appear during the chart pen adjusting procedure one of the following problems probably occurred 1 There was not a 4 20 mADC analog signal to the recorder analog channel you selected while adjust...

Страница 16: ...N OF DECIMAL WHOLE NUMBER TO HEXADECIMAL NUMBER 1 Divide the decimal number by 16 Example 57420 16 3588 75 2 Multiply only the fractional part of the product by 16 to arrive at the first character in...

Страница 17: ...lue of the next character Example 224 0 224 3 Multiply the previously found product by 16 Example 224 X 16 3584 4 Repeat steps 2 and 3 in a cyclical fashion until you have added the last hexadecimal c...

Страница 18: ...18 INSERT DWG 600662 9999 3000 RECORDER ASSY DWG...

Страница 19: ...15 SPACER 6 EA 2 0 34 400006 0025 SET SCREW 4 40 X 3 16 EA 1 0 35 524720 CHART CLAMP BODY EA 1 0 36 400006 0071 SET SCREW 5 40 X 5 16 EA 1 0 37 512610 COVER W LOGO EA 1 0 38 524743 CHART KNOB EA 1 0 3...

Страница 20: ...that pen arm transport tie down is removed from unit Increase damping See IOM page 10 Ok Now CONTACT FACTORY Will pen arm move with input now CONTACT FACTORY YES GO TO NEXT PAGE Do pen arm display ag...

Страница 21: ...Loop Check chart rotation speed chart knob tightness power outages motor backlash Chart turn ok CONTACT FACTORY Chart turn ok YES NO Fast Slow Not at all NO YES YES 3000 should be operating properly...

Страница 22: ...CULAR PURPOSE Eastech Badger shall not be liable for any defects attributable to acts or omissions of others after shipment nor any consequential incidental or contingent damage whatsoever NUCLEAR DIS...

Отзывы: