ECA 450
Operation
Instruction 0024-9400
19
2.10 Printing Data
By pressing the
key, the data which is currently being displayed in
either the Combustion Test or Pressure screen is printed on the analyzer’s
internal printer. Note that the contents of no other screen can be printed.
Data which has been stored in memory can also be printed by first displaying
the contents of the desired memory location as described in Section
2.9
Recalling Test Data Stored in Memory
.
User Name Line 1
User Name Line 2
User Name Line 3
BACHARACH, INC.
ECA 450
SN: xxxxxx
====================
Test ID Line 1
Test ID Line 2
Test ID Line 3
TIME 04:27:35 pm
DATE 01/20/2000
FUEL
Natural Gas
O2 4.0 %
CO 12 ppm
EFF 82.2 %
CO2 9.5 %
T-STACK 374 °F
T-AIR 68 °F (T)
EA 21 %
NO 18 ppm
NO2 6 ppm
NOX 24 ppm
SO2 1 ppm
HC 0.01 %
CO( 3) 13 ppm
NO( 3) 19 ppm
NO2( 3) 6 ppm
NOX( 3) 25 ppm
SO2( 3) 1 ppm
PRESSURE –0.02 inwc
---------------------
COMMENTS:
Sample Printout
User name information as
entered in Section 2.17.14
Test identification information
as entered and selected per
Section 2.17.8
Test data as measured and
calculated by the analyzer
Optional pressure printout as
selected in Section 2.17.17