![B meters MAG Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/b-meters/mag/mag_instruction-manual_3072628043.webp)
43
MAG
User Manual v2.0
5.3.3 Output 4…20mA
Note 1: The pulse output and the output 4...20 mA is available only in loop powered mode in converters
battery version.
5.3.4 MODBUS RS485 interface
The MODBUS RS485 interface is available between the terminals 13 - 14 - 15 which are positioned in the
converter board. (Fig. 66).
The communication interface RS485 is used in combination with MCE-link software or with other
computer systems compatible with the MODBUS RTU standard; for further information, see the
MODBUS address manual.
Loop powered
The receiver 4…20mA connected to the instrument is loop powered,
which feeds by itself the current in loop.
[Loop voltage 24Vdc; maximum impedance 800 ohm].
1
12
34
56
78
SINK
-
+
mA
Active powered version
The receiver 4…20mA connected to the instrument is a passive
milliamp-meter; the internal
MAG
24Vdc power supply must be
connected as shown in Figure 65.
[Loop voltage 24Vdc; maximum impedance 800 ohm].
1
12
34
56
78
SOURCE
+
-
mA
+ -
24V
Fig. 66 | Output RS485
Fig. 64