H3000 Pilot Handbook___________________________________________________
HB-3001-02
96
FAULT DIAGNOSIS
Fault 100 – Pilot not Commissioned
Fault Description
The rudder end stops on the Pilot have not been commissioned, or the
memory has been corrupted.
Remedial Action
1)
Has the Pilot ever been successfully commissioned?
Yes go to step (4)
No
go to step (2)
2)
Carry out the Dockside commissioning procedure (see page 56).
Display the Pilot screen, move the helm, does the rudder indicator
function?
Yes go to step (4)
No
go to step (3)
3)
The rudder indicator on the Pilot screen will not function if invalid
rudder end and mid points have been entered. Check the rudder
reference unit installation (see page 91) is such that the voltage
difference between the port and starboard end stops is a minimum of
1.0 volt. After checking repeat step (2).
4)
If the rudder has previously been successfully commissioned then the
fault is likely to be due to memory corruption. This may be due to a
recent change of software version or severe interference (e.g.
lightning).
We recommend that you reset the Pilot computer (node 18) and
attempt to re-commission the Pilot. If this fails contact your local
specialist dealer.
Содержание H3000 Pilot
Страница 1: ...Pilot Handbook www bandg com ...
Страница 106: ......
Страница 115: ...___________________________________________________H3000 Pilot Handbook HB 3001 02 9 Type 1 and 2 Ram Drive Dimensions ...
Страница 117: ...___________________________________________________H3000 Pilot Handbook HB 3001 02 11 Type 3 Ram Drive Unit Dimensions ...
Страница 118: ...H3000 Pilot Handbook___________________________________________________ HB 3001 02 12 Type 3 Ram Bolt Detail ...