___________________________________________________H3000 Pilot Handbook
HB-3001-02
75
Clutch Voltage Selection
The ACP computer unit can output different clutch/solenoid voltages
depending upon the size of the rudder drive unit fitted. The
clutch/solenoid valve is only required for rams or rotary drive units. This
is achieved by setting dip switches on the computer drive PCB in the lid
of the computer unit.
Set the switches as per the table below. The default setting is 9V, (switch
4 ON) suitable for size 1, 12V rams and size 2, 12V rams.
DIP Switch
Clutch Voltage Drive
Size/Type
1 24V
24V
Rotary
2
18V
Size 3, 24V Ram
3 12V
12V
Rotary
4
9V
Size 1 and 2 12V Rams
ACP DIP Switch Selection
Note:
when using drives from another manufacturer, it is important to
refer to the documentation supplied with that drive to determine the
correct clutch voltage selection. Refer to the manufacturer of the drive for
further information.
Содержание H3000 Pilot
Страница 1: ...Pilot Handbook www bandg com ...
Страница 106: ......
Страница 115: ...___________________________________________________H3000 Pilot Handbook HB 3001 02 9 Type 1 and 2 Ram Drive Dimensions ...
Страница 117: ...___________________________________________________H3000 Pilot Handbook HB 3001 02 11 Type 3 Ram Drive Unit Dimensions ...
Страница 118: ...H3000 Pilot Handbook___________________________________________________ HB 3001 02 12 Type 3 Ram Bolt Detail ...