HTY70 

 

 

 

 

 

 

 

 

Room temperature/humidity sensor 

TY70 

 

 

 

 

 

 

 

 

Room temperature sensor 

HY70 

 

 

 

 

 

 

 

 

Room humidity sensor 

 4 

 

  

   

  

Neosensor 

 

 

 

 

 

 

 

 

Neosensor high sensitive type 

  

     

 

 

Fixed 

 

 

 

 

 

 

 

 

24 V DC / 24 V AC 

 

 

 

 

 

 

 

 

No power required 

 

 

 

 

 

 

 

 

No humidity sensing 

 

 

 

 

 

 

 

 

1 V DC to 5 V DC 

 

 

 

 

 

 

 

 

0 V DC to 10 V DC 

  

 

   0  

 

 

No 

temperature 

sensing 

  

 

   P  

 

 

RTD 

(Pt100) 

  

 

   K  

 

 

RTD 

(Pt1000) 

  

 

    0 

 

 

Fixed 

  

 

     

 

Lead 

wire 

connection 

  

 

     

 

Modular 

connection 

(Modular jack is provided on the product.)

 

 

 

 

 

 

 

 

blank 

With company logo 

 

 

 

 

 

 

 

 

-1 

Without company logo 

RTD: Resistance temperature detector 
 

Regarding the available model numbers, refer to the table below. 

Available model numbers 

Model number 

Type 

Power 

Humidity output

Temperature 

output 

Signal output wire 

connection 

Company 

logo 

HTY7043T1P00 

Yes 

HTY7043T1P00-1 

Neosensor 

24 V DC/AC 

1-5 VDC 

RTD (Pt100) 

Lead wire connection 

No 

HTY7043T6P00 

Yes 

HTY7043T6P00-1 

Neosensor 

24 V DC/AC 

0-10 V DC 

RTD (Pt100) 

Lead wire connection 

No 

TY7043Z0P00 

Yes 

TY7043Z0P00-1 

Neosensor 

No power 

N/A 

RTD (Pt100) 

Lead wire connection 

No 

TY7043Z0P01 

Yes 

TY7043Z0P01-1 

Neosensor No 

power 

N/A 

RTD (Pt100) 

Modular connection 

No 

TY7043Z0K00 

Yes 

TY7043Z0K00-1 

Neosensor 

No power 

N/A 

RTD (Pt1000) 

Lead wire connection 

No 

TY7053Z0P00 

Yes 

TY7053Z0P00-1 

Neosensor  
high sensitive type 

No power 

N/A 

RTD (Pt100) 

Lead wire connection 

No 

HY7043T1000 

Yes 

HY7043T1000-1 

Neosensor 

24 V DC/AC 

1-5 VDC 

N/A 

Lead wire connection 

No 

HY7043T6000 

Yes 

HY7043T6000-1 

Neosensor 

24 V DC/AC 

0-10 V DC 

N/A 

Lead wire connection 

No 

 

Содержание HTY7043T1P00

Страница 1: ...sing Neosensor is thus suitable for various applications such as commercial building air conditioning or other indoor uses Note The specification data of the two wire 4 20mA output model of Neosensor...

Страница 2: ...bligatory action to prevent possible danger The symbol inside graphically indicates the actual action to be carried out For example the sign on the left indicates general instructions CAUTION Use the...

Страница 3: ...ow Available model numbers Model number Type Power Humidity output Temperature output Signal output wire connection Company logo HTY7043T1P00 Yes HTY7043T1P00 1 Neosensor 24 V DC AC 1 5 VDC RTD Pt100...

Страница 4: ...iring Thermoplate for open wiring is used for open wiring installation Part No DY2000A3021 For mounting three Neosensor crosswise Auxiliary device Multi Thermocase Model TY1100Z LAN cable Part No DY72...

Страница 5: ...tion resistance Min 500 V DC 20 M Withstand voltage 500 V AC applied for 1 min with max of 1 mA leakage current between housing and terminals Environmental conditions Rated operating condition Limit o...

Страница 6: ...tead of lead wires Model TY7043Z0P01 1 Figure 1 Mounting dimensions mm Neosensor with Wall direct mounting kit Neosensor high sensitive type Note For wiring secure more than 15 mm clearance inside the...

Страница 7: ...unting surface when installing Neosensor with Thermoplate mounting kit 2 The number of lead wires differs depending on the models Note that the Pt100 temperature sensor model with modular connection h...

Страница 8: ...th Thermoplate mounting kit Figure 5 Mounting dimensions mm Neosensor high sensitive type with Thermoplate mounting kit on Thermoplate Thermoplate mounting kit Figure 6 Dimensions mm Mounting plate of...

Страница 9: ...sensor model with modular connection has a modular jack instead of lead wires Model TY7043Z0P01 1 Figure 7 Mounting dimensions mm Neosensor not covered with Multi Thermocase mounting kit Multi Thermoc...

Страница 10: ...rated by office device or equipment for example stays on Air circulation is interfered by furniture or door for example Temperature and or humidity sensing is affected by draft downdraft and hot cold...

Страница 11: ...14 5 Set the depth change levers on the bilateral sides of the Neosensor main unit to the upper position indicated with L shown in Fig 17 6 Mount the main unit of Neosensor on the main unit of the Wa...

Страница 12: ...d with L shown in Fig 17 6 Mount the main unit of Neosensor on the main unit of the Wall direct mounting kit with four mounting screws M3 16 supplied with Neosensor 7 Attach the cover back to the Neos...

Страница 13: ...on the bilateral sides of the Neosensor main unit to the upper position indicated with L shown in Fig 17 7 Mount the main unit of Neosensor on the main unit of the Thermoplate mounting kit with four...

Страница 14: ...lled with its cover removed IMPORTANT Before installing Neosensor in the Multi Thermocase be sure to set the depth change levers on the bilateral sides of the Neosensor main unit at the lower position...

Страница 15: ...pth change Raising the Neosensor main unit 3 Set the depth change levers located on the bilateral sides on the main unit front surface at the lower position The levers are factory set at the upper pos...

Страница 16: ...ck Blue Black 24 V AC DC 1 5 V DC 0 10 V DC Power supply Humidity Models HY7043T1000 1 and HY7043T6000 1 Figure 22 Terminal wiring Humidity sensor with 1 5V 0 10V humidity output 24 V AC DC power Pt10...

Страница 17: ...sor temperature humidity sensor models IMPORTANT Use isolated transformer to supply 24 V AC power Single Neosensor must be powered by a single 24 V AC transformer If the multiple Neosensor or a Neosen...

Страница 18: ...wing Use a controller with low pass filter 40 dB or higher removal ratio in normal mode that receives signals from Neosensor For insufficient removal ratio provide an isolator on the controller input...

Страница 19: ...ration Neosensor is factory calibrated and does not require field calibration right after installation However field calibrate Neosensor if a shift in the output due to aged deterioration is found For...

Страница 20: ...ademark of Azbil Corporation in Japan or in other countries Specifications are subject to change without notice Building Systems Company http www azbil com Rev 2 0 Sep 2015 AB 7050 J AI 7050 Rev 3 2 P...

Отзывы: