5 Assembly in-roof system
In-roof System
Page 53 / 64
EN141217 Axitec GmbH, Otto-Lilienthal-Str. 5, 71034 Böblingen, Germany, +49 (0)7031 62 88-5186
NOTE
Sufficient ventilation of the PV module minimizes this loss of power.
High module temperatures decrease the system performance.
The rear ventilation in the region of the counter-lathing reduces the
module temperature and dissipates the heat upwards.
Do not hinder free air movement between the counter-lathing by
built-in components
Lead the ventilation cross-section of the counter-lathing over the
module field out towards the top onwards.
Modify the ridge as fan ridge with sufficient outflow cross-
sections.
1.
Fasten top row of the modules with the mounting brackets onto the
sheet metal connections and check whether tightly in position..
2.
Fasten sealing tape (lead role or Mageflex) to the mounting board.
3.
Cover the top edge of the field directly with a ridge tile
PIC 5-25: Connection without connecting plates
1
Photovoltaic module
4
Ridge tile
2
Mounting bracket long for
sheet metal connections
above
5
Mounting bracket
3
Sealing tape
6
Ridge fan
Connection without plates