5 Assembly in-roof system
In-roof System
Page 30 / 64
EN141217 Axitec GmbH, Otto-Lilienthal-Str. 5, 71034 Böblingen, Germany, +49 (0)7031 62 88-5186
5.2
Preparatory activities
5.2.1
Statics of the construction according toDIN 1055 /Euro code 1
Before ordering, determine the statics of the roof structure using
the Axitec documentation and take into account the applicable
standards (especially number of mounting brackets and
inventory).
5.2.2
General planning
NOTE
The respective execution of the generator field depends on the local
facts and the requests of the project..
Calculate the grid dimension:
(Dimensions of laminate see Appendix)
-
Grid dimension horizontal: R
hor
[mm] = laminate width [mm] +
32 mm (frame profile)
-
Grid dimension vertical: R
ver
[mm] = laminate height [mm]
1.
Grid sizes to be multiplied by the corresponding number of module
columns i.e. module rows::
-
Generator width [mm] = R
hor
[mm] x number of columns of
modules
-
Generator height [mm] = R
ver
[mm] x number of module rows
2.
Include the edge frame profiles to the calculation, because they have
no other overlapping element:
NOTE
The following information to be checked on site with the local
conditions.
NOTE
Take into consideration the overlapping frame profiles for the calcula-
tion of the grid dimension .
Grid dimension
Generatorfeld