![Axis 70 Скачать руководство пользователя страница 154](http://html.mh-extra.com/html/axis/70/70_user-manual_3039788154.webp)
The Parameter List
User’s Manual
154
ExternalLink
=www.company.name Specifies the URL to a customized link, e.g. to your
company’s web site. The link will be available from the AXIS
7000 Web browser interface.
ExternalImage
=
Specifies the URL to the image that will indicate the
customized external link.
SMB]
ServerName
=AXISCD0000
The server name in the SMB environment. Default is
AXIS<nnnnnn>
where
nnnnnn
are the last six digits of the
serial number.
Domain/GroupName
=
Name of the AXIS 7000 workgroup in SMB. If not specified,
the AXIS 7000 will appear in the workgroup that comes first
in alphabetical order.
NTDomainInstallation
=no
Set to
yes
when you want to install the AXIS 7000 in an NT
domain.
SNMP]
GetCommunityName
= public
Specifies the community that has read only access to all
supported SNMP objects except WriteCommunity,
SupervisorPassword and ftpPassword. It corresponds to the
ReadCommunity SNMP object.
TrapDestination
= 0.0.0.0
Specifies the IP Address which SNMP traps are sent to. It
corresponds to the TrapAddress SNMP object. Default is
0.0.0.0
, which means that all SNMP traps are disabled.
TrapCommunityName
= public
Specifies the community for all generated SNMP traps. It
corresponds to the TrapCommunity SNMP object.
SystemContact
=
Optional entry which should be in plain text and may be
used to show the name of the system contact person.
SystemName
=
Optional entry which should be in plain text and may be
used to show the name of the system.
SystemLocation
=
Optional entry which should be in plain text and may be
used to show the location of the system.
AuthenticationTrap
= disabled
Enables or disables the SNMP authentication failure traps. It
corresponds to the snmpenableAuthenTraps (MIB-II) SNMP
object.
Clients]
InformationLevel
= Basic
Specifies the default amount of information to be
transmitted with a scanned image. If not set for a
destination, this setting will be used. Valid values are
Nothing, Basic
or
Complete. Basic
includes information
about the AXIS 7000, the connected scanner device, the
parameter settings used when scanning etc.
Complete
also
includes the image-related profile settings.
FTPDefaultUser
= anonymous
If not set for a destination, this username will be used.
FTPDefaultPassword
If not set for a destination, this password will be used. This
field can also contain the identity of the user transmitting
the scanned image. This is useful for administrative
purposes.
Parameter name
Value
Description