103
Image
Set Duration
(5 to 255 seconds)
Set the time interval to wait before triggering an alarm once the criteria
(sensitivity level) for “video freeze” has been detected.
Note:
1. It may take up to one second more than the value of the “Set Duration”
parameter to trigger a video freeze alarm.
2. This item only appears for Rainier 3G Plus – (1 card).
Video Black (no video) and Video Freeze cannot happen simultaneously. When both conditions exist,
Video Black has the higher priority.
Likewise, both functions are not available for analog input signal.
Image
Border
Red Color
(On / Off)
Set the image border to the color
Red
as warning.
Flash
(On / Off)
Set the image border to
Flash
as warning.
Audio Alarm
Enable
(On / Off)
Activate audio loss detection to be monitored on a single channel or
group.
No Audio Alarm
(Single Meter)
(On / Off)
Activate the alarm that is triggered when no audio is detected.
Border Red Color
(On / Off)
Set the image border to the color
Red
as warning.
Flash
(On / Off)
Set the image border to
Flash
as warning.
Response Time
Signal In/Out
(0.25 to 49.75)
Set the
Signal In
/
Out
alarm response time, such as when inputting the
signal or change of status from “abnormal” to “normal.”
Alarm Sound
Video
Enable
(On / Off)
Activate playback of alarm sound when no video / video black/freeze is
detected in a particular window.
Note: To enable alarm sound playback, click “Start Alarm Sound
(System)” icon (will become grayed-out).
Set Playback
Duration
(5 to 3600
seconds,
Always on)
Set “video alarm” sound playback duration (second) for specific window.
Note: To shut off alarm sound playback before the time set has elapsed,
click “Stop Alarm Sound (System)” icon (will become grayed-out).
File
Change
Click the cell’s rightmost portion “change” button
to select the audio file
as the video alarm sound for the particular window.
Note: Only the “WAV” audio file format is supported.
Audio
Enable
(On / Off)
Activate playback of alarm sound when no audio is detected in a window.
Note: To enable alarm sound playback, click “Start Alarm Sound
(System)” icon (will become grayed-out).
Содержание Titan 9000 series
Страница 1: ...User Manual Titan 9000 Multiviewing experience taken to the next level Revision 1 0 0 May 2014 ...
Страница 103: ...97 Image Layout and Alarm Trigger Change Audio meter scale ...
Страница 117: ...111 Figure A 4 LCD Panel Menu Tree ...
Страница 134: ...128 Step 5 Manually re size and rearrange the 5 windows to obtain the below example display ...
Страница 145: ...139 Sample illustration 3 Figure C 3 Audio Output From Chassis ID 2 Card ID 4 Image 3 Plus Chassis ID 1 Headset ...