Chapter 7: Plug-In Controls
89
EQ Edit and Display Controls
Save As Switch
The Save As switch performs the Save As command in the
Plug-In settings menu, which saves a new settings file for the
plug-in.
To save an EQ plug-in setting from D-Control:
1
Press the Save As switch in the Edit and Display controls of
the Dynamics section. The Save As switch flashes while the
Save Settings dialog is open.
2
Type a name for the plug-in setting.
3
Do one of the following:
• Click
OK
to save the settings and close the dialog.
• Press the flashing Save As switch to save the settings and
close the dialog.
• Press the Escape switch to exit the dialog without saving
the settings.
Lock Switch
The Lock switch is used to lock the focus of the EQ section on
the current plug-in. When the plug-in focus is locked, the cur-
rent plug-in remains in the EQ section, even when a different
track is focused on D-Control. This switch lights when the
plug-in focus is locked.
Compare Switch
The Compare switch toggles the Compare button in the
plug-in window, which alternates between the currently saved
plug-in setting and any changes you have made.
Automation Switch
The Automation switch lets you enable EQ parameters for au-
tomation by touching or pressing their controls in the EQ sec-
tion only.
In Automation mode, the Auto switch is lit. While in this
mode, the Auto indicator for any rotary encoder enabled for
automation is lit red, and the switch for any parameter en-
abled for automation is lit.
To toggle automation on and off for individual EQ parameters:
1
Press the Automation switch.
2
Touch the rotary encoders or press the switches in the EQ
section for which you want to toggle automation.
3
Press the Automation switch again to exit Automation mode.
To toggle automation on and off for all parameters of an EQ
plug-in:
1
Press the Automation switch.
2
Do one of the following:
• Hold Alt (Windows) or Option (Mac).
– or –
• Hold Do to All.
3
Touch any rotary encoder or press any switches in the EQ
section.
4
Press the Automation switch again to exit Automation mode.
Edit and Display controls in the EQ section
Compare switch
Cycle switch
Master Bypass switch
Save As
switch
Lock
switch
Automation switch
Automation Safe switch
Window switch
Содержание 9320-65044-00
Страница 1: ...D Control Guide...
Страница 6: ...D Control Guide vi...
Страница 7: ...Part I Introduction...
Страница 8: ......
Страница 12: ...D Control Guide 6...
Страница 19: ...Part II Installation...
Страница 20: ......
Страница 38: ...D Control Guide 32...
Страница 52: ...D Control Guide 46...
Страница 53: ...Part III Reference...
Страница 54: ......
Страница 76: ...D Control Guide 70...
Страница 132: ...D Control Guide 126...
Страница 154: ...D Control Guide 148...
Страница 170: ...D Control Guide 164...
Страница 174: ...D Control Guide 168...
Страница 184: ...D Control Guide 178...
Страница 185: ......