FLSC 05 w/FLI 225 Instrument Service Manual
87
10 Replacing Weigh Bars on the FLSC 05 Carriage
5.
Make sure the cables are secured and will not get pinched when the carriage
is reassembled.
6.
Torque each of the Weigh Bar bolts to 65 foot pounds. Start at the top then go
to the bottom bolt. Always tighten opposites. Follow the pattern shown in
Figure 10.10.
Figure 10.10 Weigh Bar bolt tightening pattern
7.
Using a hoist and strap or plenty of manpower, slowly lower the back of the
carriage over the front, lining up the Weigh Bars with their associated holes in
the back plate. Be sure to keep the Weigh Bar cables and ends positioned so
they are not pinched as the two pieces are brought together. The cables
should exit the shields at the notches in the carriage. See Figures 10.11 and
10.12.
Figure 10.11 Joining the carriage halves
Содержание FLI 225
Страница 10: ...10 FLSC 05 w FLI 225 Instrument Service Manual ...
Страница 11: ...FLSC 05 w FLI 225 Instrument Service Manual 11 1 FCC and EMC Declarations of compliance ...
Страница 70: ...70 FLSC 05 w FLI 225 Instrument Service Manual Chart of ASCII Characters ...
Страница 104: ...104 FLSC 05 w FLI 225 Instrument Service Manual 11 3 Exploded View of FLSC 05 Carriage Assembly ...
Страница 106: ...106 FLSC 05 w FLI 225 Instrument Service Manual 11 5 Exploded View of FLI 225 AWT05 500348 ...
Страница 109: ......