48
2.3 C
ONNECTING
THE
SENSORS
ALS
306
309
Pin assignment
[86] Pin assignment for OD sensor connection
Setting the roll diameter
Prerequisite:
– OD sensor is installed an activated.
– Label material roll with the required remaining diam-
eter is prepared.
Measure the diameter of the prepared roll.
Loosen the thumb screws [88A] at the reflector.
Shift the reflector to position A [87A] or B [87B]
(long holes) according to the measured roll
diameter (--> tab.). Retighten the thumb screws.
Insert the prepared label roll.
Loosen the thumb screws [88B] at the sensor.
Rotate the sensor, until the light beam does not
meet the reflector any more.
– The LED at the sensor is off.
Slowly rotate the sensor backwards, until the light
beam meets the reflector.
– The LED at the sensor lights up.
Rotate the sensor further, until the light beam is
covered by the label roll.
– The LED at the sensor goes out.
Tighten the thumb screws.
Pin
Assignment
1
+24 V
2
not used
3
Ground
4
Sensor signal
Roll Ø
in mm
Roll Ø
in Inch
Reflector
position
38-122
1.5-4.8 A
51-135
2.0-5.3 B
1
2
3
4
[87] Setting the OD sensor
A
Reflector position A (solid line)
B
Reflector position B (dotted line)
C
Sensor
D
Rotating range of the sensor
[88] Rear view on the OD sensor.
A
B
C
A
B
D
C
A
B
Содержание ALS 306