background image

   

   

 
 

 

 

 

 

Iwashita Engineering Inc.

 

ACCURA9/9L 

INSTRUCTION MANUAL

 

 

Ver.3.1 

 

 

 

 
 
 
 
 
 
 
 

IEI

   ’04/03/22 

 

Summary of Contents for ACCURA9

Page 1: ...Iwashita Engineering Inc ACCURA9 9L INSTRUCTION MANUAL Ver 3 1 IEI 04 03 22 ...

Page 2: ... SAMP setting screen 18 7 4 STEADY MODE 20 7 4 1 Shot screen 20 7 4 2 Data editing screen 22 7 4 3 D SAMP setting screen 24 7 5 Viscosity Mode 25 7 6 RS232C communication setting 26 7 7 Error screen 26 8 Data Sampling 29 9 Change barrels 33 10 Remote Mode 34 10 1 RS232C Communication 35 10 2 Parallel Communication 50 10 2 1 Input signal 50 10 2 2 Output signal 53 11 Interface of Input Output signa...

Page 3: ...may get an electoric shock z Do not exceed the applicable air pressure source range or it may get damaged z Do not use the product in the environment under high temperature high humidity dust and gas corrosion chloride acid and alkali or you may get an electoric shock z Do not convert or remodel the products We are not responsible for any accidents and damages caused by it z Use the instructed vol...

Page 4: ...c by 0 001 sec Shot Counter 6 digits 000000 999999 Operation Mode AUTO Mode STEADY Mode VISCOSITY Mode RS232C Mode Remote Mode RS232C Mode EXIT I O Foot Switch Shot Signal to start and end Isolation by Photo coupler Memory backup Lithium primary battery approx 1 5 year lifespan under 16 hour poweroff a day Operating temperature 5 40 no dew Overall dimension W280mm D300mm H100mm Chassis Weight 8kg ...

Page 5: ...for shot volume Compensate shot pressure automatically in order to make constant shot volume by not only AUTO mode but also STEADY mode Compensation for vacuum Compensate vacuum level automatically and prevent bubbling in a barrel and dripping of materials Pressure compensation for viscosity Stabilize shot volume for materials which may change its viscosity Hardening softening or mixed with harden...

Page 6: ...l of Controller IEI POWER ON OFF INDICATOR MODE OFF REMOTE MENU CLR RST CTRL SHIFT RETURN H AIR OUT ACCURA9 Each parts name Power switch SHIFT key LCD panel Cursor key Air out port RETURN key MODE key CLR RESET key 6 OFF shot key Cursor key REMOTE key CTRL key MENU key H key Cursor key Cursor key are key names ...

Page 7: ...ear Panel of controller I O PORT2 I O PORT1 FUSE AC IN RS232C SHOT CON GND EJECTOR AIR IN Components Names Air Import Port Exhaust silencer Control connector Outer input output connector Power source connector Fuse Ground RS232C connector ...

Page 8: ...bricated dry air or air filtered through submicron filter or micromist filter should be used 4 Connect adapter assembly with air out port on front panel 5 Prepare the barrel for dispensing materials Before filling the material into the barrel clean the barrel and the needle by airbrushing to take off dust and water 6 Assemble the needle on the barrel and fill the material into the barrel up to 70 ...

Page 9: ...ters Screen Sys Parameters System 01 Press kPa RETURN The system parameter is shown on the screen ET k em System information Unchangable 9L Press I RN key after checking system parameters Take your hand off from the CTRL CLR RES ey Syst 01 Standard specification Accura9 21 Low pressure specification Accura nput the pressure unit Unchangable Press RETU 3 System Initialized Screen Syetem Initialized...

Page 10: ...o change each screen in the AUTO STEADY Mode Each screen changes as following steps MODE Key Shot Data Edit D SAMP Function Setting MODE Key MODE Key To input numerical data Input numerical data as follows 1 key Put the cursor on the numerical data 2 Keys Increase or decrease the figures 3 CLR RESET Key clear the figures and return to initial value To select input menu If there are multiple input ...

Page 11: ...the mode with the mode key During selecting the mode the mode is shown in capital letters and circled by Press the return key after selection of the mode key to carry out each mode Finish each mode Press H Mode key to finish each mode And then appear the mode selection screen Clear the data for all channels Press CTRL CLR RESET keys to clear the data for all channels DATA CLEAR YES RETURN NO CLR R...

Page 12: ...100 Sp 100 0 Sc 000300 Cm OFF Shot Screen Level Compensation Auto Shot Ch 00 St 00 100 Sp 100 0 Sc 000300 Cm LE VC EMP DE Shot Screen Viscosity compensation 01 30 Auto Shot Ch 00 St 00 100 Sp 1 000 Sc 000300 Cm VI Shot Screen Intermittent Compensation Auto Shot Ch 00 St 00 100 Sp 100 0 Sc 000300 Cm IN Ch Channel number Sp Shot pressure of channel Unit kPa St Shot period Unit second Sc Shot counter...

Page 13: ...ease slightly when dispense continuously with a barrel filling with material Pressing UP key or DOWN key can solve this problem by changing the shot period to adjust the dispensing volume This function can be carried out while other calibrating functions are working in parallel The fluctuating volume can be allowed in the setting time 20 except for the following case 1 If the initial setting dispe...

Page 14: ... In order to meet the user s requirement Foot switch FSW Exit I O Exit and RS232C RS2 can be used for dispensing Every time on entry of Remote key FWS EXT and RS2 are shown When only foot switch is used it can be shifted to input through LCD panel by pressing SHIFT REMOTE key Refer to 10 Remote Mode in the instruction manual for details End AUTO mode To end AUTO mode enter H MODE keys except when ...

Page 15: ...reen Intermittent Compensation Auto Edit Ch 00 St 00 100 Sp 100 0 Sc 000300 Cm IN 500 100 BS 30 Ch Input the channel number for data editing Sp Input the shot pressure Unit kPa St Input the shot time Unit second If the level compensation is needed input 30msec or more Sc Input the shot count The count up screen will appear when the shot counter reaches the setting shot count Input 0 zero when not ...

Page 16: ...unt up is not set To check the shot volume The shot volume can be checked by OFF Key Adjust values of Sp and St to get the suitable shot volume To save the data After input each data save the data by pressing RETURN Key Renewal of data should not be done without pressing the RETURN Key even if the values are changed on the screen After saving the data the following screen is shown for confirmation...

Page 17: ...ged automatically corresponding to the lapsed time This will be used for the material when viscosity varies Set Cm on the edit screen VI and input the number of viscosity compensation table at VISCOSITY mode The lapsed time is shown at the upper left of dispense screen while compensating viscosity Press CLR Key to clear the lapsed time and return shot pressure to initial setting values Intermitten...

Page 18: ...ing Screen D Samp Menu Ch 00 Bot Level NOD Top Level NOD Emp Level OFF Ch Current selected channel Bot Level Down load the sampling data at bottom level into ROM and set the function 1 Top Level Down load the sampling data at top level into ROM and set the function 1 Down load the sampling data for vacuum into ROM at other than level compensation 2 Emp Level Down load the empty level and set the f...

Page 19: ...ampling data into the program Refer to 8 Data sampling for at the vacuum sampling data except for the data sampling data at level compensation at the empty level and at the level compensation Memorize the sampling data at the level compensation into ROM in order of Bot Level and Top level The data sampling at Bot_Level and Top_Level enables shot compensation and vacuum compensation downloading the...

Page 20: ... Steady Shot Ch 00 St 00 000 Sp 100 0 Sc000300 Cm OFF Shot Screen LevelCompensation Steady Shot Ch 00 St 00 000 Sp 100 0 Sc000300 Cm LE VC Shot Screen LevelCompensation Steady Shot Ch 00 St 00 000 Sp 100 0 Sc000300 Cm LE VC EMP DE Shot Screen Cartridge Compensation dy ShSteaot Ch 00 St 00 000 Sp 100 0 Sc000300 Cm CA Ch Shot channel number Sp Set the pressure Unit kPa St Shot time during the time f...

Page 21: ...een Remote Mode Remote Mode Screen Steady Shot EXT Ch 00 St 00 000 Sp 100 0 Sc 000300 Cm LE VC Enter into Remote Mode with Remote key Dispensing is operated by signal from external input in the remote mode In order to meet the individual user s requirements the foot switch FSW EXIT I O EXT and R S232C RS2 can be used for dispensing Each time when press the REMOTE key FSW EXT and RS2 will appear Wh...

Page 22: ...ompensation Steady Edit Ch 00 St 00 000 Sp 100 0 Bs 30 Cm CA 001000 100 10 Ch Enter the channel number for data editing Sp Entrer the shot pressure Unit kPa Cm Select the shot compensation OFF No shot compensation LE Level compensation CA Cartridge compensation Mt When compensate the level enter the minimum shot period for sampling Shown on the shot compensation in LE Enter more than 30msec as min...

Page 23: ...screen Save the data Save the data by RETURN key During saving the data the following screens will appear for confirmation Press RETURN key to save the data press CLR RESET key to stop it SAVE DATA YES RETURN NO CLR RST Confirmation Screen STEADY MODE SAVING DATA Data Save Screen Remark If the saving data is carried out after having changed the shot pressure the minimum shot period and the size of...

Page 24: ...he same channel Compensation on cartridge use When a large volume cartridge 170cc and 340cc is used for linear dispensing the dispense line would be thin because the material runs out and not dispensed soon after start dispensing In order to avoid this situation this product can set the shot pressure to be increased soon after dispensing when coming to the predetermined shot period Set Cm on edit ...

Page 25: ... item with MENU key Press the MENU key to go forward and press SHIFT MENU Key to go back Press H MENU key to return to Tbl_No Input the data number and viscosity compensation data Enter the lapsed time min the pressure rate of change the hardening UP and softening DOWN viscosity per data number Enter the data number from the number 01 in order Enter the lapsed time by minute since changing barrels...

Page 26: ... Stop bit 1 2 The initial setting 2 F U N C T I O N S Operation Select the entering item with Menu Keyt Press the Menu Key to advance one step and press the SHIFT Menue Key to return to one step Press H Menue Key to return to Baudrate Set the communication function Enter all data for Baudrate Parity Bit Length and Stop bit with cursor key Complete the RS232C Mode Press H Mode key to complete the R...

Page 27: ...the barrel or cartridge reaches the initial setting minimum empty level EMPTY DETECTED Enpty Detect Screen RS232C EMPTY DETECTED Enpty Detect Screen 3 RS232C Check Sum Error This screen appears when there is difference between values of checksum transmitted in RS232C and of checksum caliculated inside of dispenser RS232C CHECK SUM ERROR Check Sum Error Screen 4 RS232C Status Error This screen appe...

Page 28: ... Time Over Error Screen How to release The error with buzzer sound is cleared after releasing the error In case of 1 2 and 3 Key operation Press CLR RESET key EXIT I O Enter the alarm clear signal from outside RS232C Transmit the command from the host computer to clear the alarm Or press the CLR RESET key In case of 4 and 5 Press the CLR RESET key Command from the host computer to clear alarm is u...

Page 29: ... Confirmation Screen BARREL Bottom READY YES RETURN NO CLR RESET Set the barrel filled in the material up to the lower limit and press the RETURN key Press the CLR RESET key to stop 3 Bottom sampling Screen Bottom Level Ch 00 Vc Press 010 0 St Press 120 0 Enter the vacuum pressure Vc Press and the shot pressure St Press at the lower level Dispense by OFF key set the shot volume to be equivalent to...

Page 30: ...ut material dropping and bubbling Input the Vt and Vi more than 0 030 sec If O K press the RETURN key Press SHIT CLR RESET key to stop 8 Sampling Screen Sampling Mode DATA SAMPLING The dispensing for the downloading of sampling data is carried on a few times During the sampling this screen is shown After the sampling D SAMP screen is shown The procedure at the upper level of barrel is completed 9 ...

Page 31: ...Continue to dispense After saving the data by RETURN key D SAMP function setting screen is shown 11 D Samp Function Setting Screen D Samp Menu Ch 00 Bot Level ON Top Level ON Emp Level ON In order to use the Empty Alarm function set Emp_Level ON on the D SAMP screen If setting OFF the Empty Alarm function doesn t work Check the Empty Level Check at the shot screen to fill the shot material in the ...

Page 32: ...y to shift the next screen 2 Barrel Confirmation Screen BARREL Top READY YES RETURN NO CLR RESET Set the barrel filled materials up to the upper level and press RETURN key Press CLR RESET key to stop 3 Top Sampling Screen Top Level Ch 00 Vc Press 015 0 Vt 00 500 Vi 01 000 Input the vacuum pressure Vc Press the vacuum time Vt and the vacuum interval time Vi with OFF key while keeping off material d...

Page 33: ...mode is Foot Switch FSW EXIT I O EXT or RS232C RS2 When the remote mode is EXIT I O EXT it is possible to change the barrels by the signal to clear the setting signal from outside When the remote mode is RS232C RS2 it is possible to change barrels by the command to clear the setting data 2 Completion of Barrel Changing CHANGE SAME BARREL The left screen will appear after completing to change barre...

Page 34: ...o Shot Ch 00 St 00 100 Sp 100 0 Sc 000300 Cm LE VC Show the shot screen at AUTO mode or STEADY mode 2 Auto Shot Remote Screen Auto Shot EXT Ch 00 St 00 100 Sp 100 0 Sc 000300 Cm LE VC After entering the REMOTE key the condition of remote mode will appear on upper right corner The controller can be controlled by means of the Foot switch FSW EXIT I O EXT and RS232C RS2 on the upper right screen mean...

Page 35: ...wledgment signal ACK is transmitted If there are some errors Non acknowledgment signal NAK is transmitted Receiving the acknowledgment signal by the sender is the completion of transmission The sender stops the transmission because of timeout when the sender does not receive the acknowledgment signal or Non acknowledgment signal within 10 seconds after transmitting the transmission request signal ...

Page 36: ...rmat Data Byte No Description Code Data length 1 Total byte Nos of and Binary Head part 10 There s Command in 3rd and 4th byte See below Data 1 n Channel Mode ASCII Check sum 2 Total byte Nos of and Binary Head 10 byte Refer below Data n byte Check Sum command Data Head consists of the left description The command confirms the kind of the data Host ACCURA9 00h ACCURA9 Host 80h Fixed value 00h Comm...

Page 37: ...0ml 4 170ml Data 1 8 6 012345 Every data is stored the first byte as the high end Omit a decimal point List of Received command description Clear count Clear shot count current count Kind Item Byte No Figure 1 Data length 1 0Ch 2 Command 2 ʼC Stored Data The data is stored at the received channel mode AUTO mode STEADY mode Kind Item Byte No Figure Item Byte No Figure 1 Data length 1 1Eh Data lengt...

Page 38: ...mode and transmit the shot end signal after shot is finished Kind Item Byte No Figure 1 Data length 1 0Fh 2 Command 2 ʼSTʼ 3 Channel Mode 2 1 Shot end Complete to shot at the STEADY mode Transmit the shot end after shot is finished Kind Item Byte No Figure 1 Data length 1 0Ch 2 Command 2 ʼSPʼ Master data request Transmit the master data of received channel Kind Item Byte No Figure 1 Data length 1 ...

Page 39: ...m operational time Vacuum operation OFF time 2 1 1 4 4 4 4 4 4 Reset Clear all of the set data The same result as when pressing the CTRL CLR RESET key Kind Item Byte No Figure 1 Data length 1 0Ch 2 Command 2 ʼRTʼ Alarm clear Release the alarm Kind Item Byte No Figure 1 Data length 1 0Ch 2 Command 2 ʼACʼ Setting clear Clear the shot count present figure Return the shot pressure and vacuum pressure ...

Page 40: ... length 1 0Ch 2 Command 2 ʼRMʼ Stored Sampling data Store sampling data in received channel mode Kind Item Byte No Figure 1 Data length 1 3Fh 2 Command 2 SS 3 Channel Mode Data1 Data2 Data3 Data4 Data5 Data6 Data7 Data8 2 1 6 6 6 6 6 6 6 6 When data is stored sampling is ON automatically at upper limit or lower limit of barrel Therefore set shot data and master data as sampling is carried out befo...

Page 41: ...quest Transmit sampling data received channel Kind Item Byte No Figure 1 Data length 1 0Fh 2 Command 2 ʼSRʼ 3 Channel Mode 2 1 Take a note of shot data and master data which are data while sampling is carrying out They are necessary when transmitting ...

Page 42: ...th 1 2Ch Data length 1 13h 2 Command 2 ʼD ʼ Command 2 ʼD ʼ 3 Channel Mode Shot period Shot pressure Shot count Shot pressure Current Shot number Current Vacuum pressure Current 2 1 5 4 6 4 6 4 ʼ0ʼ Channel Mode Shot pressure 2 1 4 ʼ1ʼ Shot end Transmit after shot is finished by shot command in the AUTO mode or by shot end in the STEADY mode Kind Item Byte No Figure 1 Data length 1 0Eh 2 Command 2 ʼ...

Page 43: ...the error ʼ1ʼ Shot count up ʼ3ʼ Empty alarm ʼ7ʼ Communication check sum error Master data Responding to the request of master data the following data are transmitted Kind Item Byte Figure 1 Data length 1 28 h 2 Command 2 ʼMDʼ 3 Channel Barrel capacity Mode Auto mode lower limit shot pressure Steady mode lower limit shot pressure Vacuum pressure at upper limit Vacuum pressure at lower limit Vacuum ...

Page 44: ...UAL Sampling data Responding to sampling data request the following data is transmitted Kind Item Byte No Figure 1 Data length 1 3Fh 2 Command 2 SD 3 Channel Mode Data1 Data2 Data3 Data4 Data5 Data6 Data7 Data8 2 1 6 6 6 6 6 6 6 6 ...

Page 45: ...leasing error by ACCURA9 Error in communication The error in below may occur in any reason n Status error When parity error overrun error or framing error occur o Time over error It occurs if communication can not finish within 10 seconds from the beginning p Check sum error It occurs when there is difference between check sum value which is sent from Host computer and calculated value from receiv...

Page 46: ...ta Shot command AUTO Shot stop command STEDY Shot data request Master data request Alarm clear Actual data corresponding t d d t Shot end ٛ Shot end Shot data Master data Error detail No transmitting if no error occurs on ACCURA9 Sampling data request Sampling data Pattern 2 ACCURA 9 9L proceeds the job corresponding to the command from Host computer after receiving it No actual data should be tra...

Page 47: ...or occurs ENQ Error detail n byte EOT ACK ENQ EOT Alarm clear n byte EOT ACK ACK ENQ Release error Error detail Release error nbyte Errror detail Shot count up Empty ditector Pattern 4 ACCURA 9 9L will transmit a message of NAK to Host computer when there is something abnormal in the data transmitted from Host computer since then will transmit the error status to Host computer E r r o r d e t a i ...

Page 48: ... s e n e l i n g E O T Pattern 6 Countermeasure for transmission time over of ACCURA9 9L HOST ACCURA9 ENQ EOT Error occurs EOT can not be receired within 10 seconds after sending ENO or no acknowledgment for data transmission when receivingEOT ENQ NAK Re execution by Host computer Pattern 7 Host computer should shift to Receiving if Host computer and ACCURA 9 9L start transmitting ENQ communicatio...

Page 49: ...G 2 TXD 3 RXD 4 RTS 5 CTS 6 DSR 7 GND 8 DCD 20 DTR 1 FG 2 RXD 3 CTS 4 GND 5 N C 6 TXD 7 RTS 8 DSR 9 DTR The following example is for connection between IBM PC AT Converter and ACCURA 9 9L for the reference IBM PC AT convertible side ACCURA9 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI 1 FG 2 RXD 3 CTS 4 GND 5 N C 6 TXD 7 RTS 8 DSR 9 DTR ...

Page 50: ... m b e r FUNCTION S1 3PIN S2 22PIN S4 4PIN S8 23PIN Specify the one place of channel number for dispense S1 5PIN S2 24PIN S4 6PIN S8 25PIN Specify the two places of channel number for dispense S8 S4 S2 S1 Channel number 0 0 0 0 0 0 0 0 1 1 0 0 1 0 2 0 0 1 1 3 1 0 0 0 8 1 0 0 1 9 Remark If the input route isn t connected to Channel Selection Signal the channel number for dispense will be shown 00 M...

Page 51: ...ng dispensing 1 CONTROLL ACTION Steady Mode SHOT START 8PIN 0 Stop dispensing This signal can be input in case of the busy signal 1 1 Dispensing Input this signal to dispense material in linear Keep dispensing until inputting 0 During dispensing 1 the busy signal shows 1 1 SHOT OFF SIGNAL I O PORT 1 7PIN Dispensing time Vacuum time CTION SHOT CONTROL A OFF 7PIN 0 Set 0 signal in usual 1 Input this...

Page 52: ...screen and or buzzer sound is reset 0 0 1 Reset settings Reset compensating condition to an initial setting Reset dispensing pressure and vacuum pressure to the initial settings Reset a number of dispensing Reset the lapsed time during viscosity compensation in use During alarm error this signal is ignored 0 1 0 Reset After input this signal the software of controller is reset and restarts from th...

Page 53: ...e BUSY SIGNAL I O PORT2 24PIN 24PIN OUTPUT CONDITION 0 Output when the controller is available to accept Input signal 1 Output 1 when the controller is unavailable to accept Input signal with exceptions of follows 1 Available to accept only 0 signal during dispensing in Steady Mode 2 Available to accept only Shot Off signal during dispensing in Auto Mode 1 During dispensing incl vacuum time and sh...

Page 54: ...r controller 1 Output if any error occurs in the dispenser controller Reset by Alarm reset of control signal if the signal turns 1 Empty Alarm Signal I O PORT2 3PIN 3PIN OUTPUT CONDITION 0 Output if Empty Alarm or Count up function does not occur 1 Output if Empty Alarm or Count up function works Output on the Alarm Error signal if this signal turns 1 with an exception of follows If select continu...

Page 55: ...6 Input D1 4S Channel selection signal two places 7 Input SHOT OFF signal 8 Input SHOT START signal 9 Input Alarm clear signal 10 Input Remote shift signal 15 GND GND 16 GND GND 17 GND GND 20 Input External power source 8V 40V SW1 EXT 21 Input External power source 8V 40V SW1 EXT 22 Input D0 2S Channel selection signal one place 23 Input D0 8S Channel selection signal one place 24 Input D1 2S Chan...

Page 56: ... source 0 2A MAX SW3 OUT 21 Power 24V power source 0 2A MAX SW3 OUT 22 Output Alarm Error signal 23 Output AUTO signal 24 Output BUSY signal 25 Output Counter signal 34 GND GND 35 GND GND 36 GND GND Remark 1 Do not connect all other ones except the above pin numbers 2 Use cable with shielding to connect with external system and gound shielding beside the external system 3 Do not tie signal cable w...

Page 57: ...ed beside dispenser PIN No Signal 1 FG 2 RXD 3 CTS 4 GND 5 N C 6 TXD 7 RTS 8 DSR 9 DTR Control Connector Pin Arrangement Connector is placed beside dispenser PIN No In Out Signal 1 Input Shot start signal 2 Input Shot start signal 3 Output Shot end signal 4 Output Shot end signal ...

Page 58: ...nput and Output Signal I O Port Signal input USER LOGIC USER SOURCE 8VDC 40VDC COM IN PUT ACCURA 9 GND 15 16 17 GND REGULATOR 5V 5V INSULATION GND ACCURA 9 5V ACCURA 9 1 2 20 21 GND ACCURA 9 5V ACCURA 9 IN PUT SW1 ISO EXT 31 32 33 INSULATION SHIELD F G ...

Page 59: ...NSTRUCTION MANUAL I O port signal output 5V ACCURA 9 OUT PUT USER LOGIC ACCURA 9 GND 15 16 17 MAX 50mA LOAD MAX 50mA LOAD GND INSULATION SHIELD OUT PUT 5V ACCURA 9 GND ACCURA 24V ACCURA 9 IN OUT SW3 I O PORT1 COM F G ...

Page 60: ...SW 3 Explanations ISO IN Supplying power to port 1 of ACCURA9 is not required External input port is required power because power is not done output from port 2 to outside ISO OU T Supplying power to port 1 of ACCURA9 is not required External input port is not required because power is done output from port 2 to outside In this case insulate it with power of external auto system Otherwise it may c...

Page 61: ...UCTION MANUAL CONNECTION OF CONTROL CONECTOR FOOT SWITCH 5V ACCURA 9 5V INSULATION GND INSULATION GND ACCURA 9 3mA USER LOGIC ACCURA 9 5V ACCURA 9 OUT PUT 1KΩ LOAD MAX 50mA GND INSULATION 3 4 GND INPUT COM SHIELD 1 2 F G ...

Page 62: ...ect alarm Remote change Reset input POWER ON Channel input S2 DON T CARE DON T CARE S4 S DON T CARE DON T CARE S8 DON T CARE DON T CARE 8S DON T CARE DON T CARE D0 D1 Select signal More than 100ms Vaccum time Shot operation BUSY SHOT START Dispense by Channel data Line AUTO SHOT END SHOT OFF Counter More than 10ms Auto Steady Vaccum time S1 ...

Page 63: ...RUCTION MANUAL Control Connector Foot Switch Timing Chart Shot start 1 AUTO MODE ON OFF Shot Stop ON OFF Shot motion Shot complete Shot start 2 Steady Mode ON OFF Shot Stop ON OFF Shot motion Shot complete 10msec or more ...

Page 64: ...ta and important data for the system may disappear completely if detaching the backup battery while turning ACCURA 9 off for a long time 5 6 hours Replace batteries as the following procedures In the event of data loss or request for us for barreries replacement please contact us Battery for use CR2032 Panasonic 1 Power off Accura9 2 Take off the chassis cover of Accura 9 Front panel Battery holde...

Page 65: ... O ring of the adapter assembly is corroded by the solvent or when it hardens replace it with a new one The adapter assembly barrel needle and O ring are consumable Specify the size and model number when ordering Trouble and Repair Please make a contact to Iwashita Engineering Inc for trouble and repair of the controller Miscellaneous When turning off controller take off asapter assembly which is ...

Page 66: ...66 ACCURA9 9L INSTRUCTION MANUAL 14 Appearance of the Controller Front view Rear view Front view Side view ...

Reviews: