43
2.3 C
ONNECTING
THE
SENSORS
ALS
306
309
2.3.3
Changing light/dark switching
at the product sensor or the
alternativ label sensor
Basically, sensors can be assigned to three dif-
ferent groups regarding the function of pin 2:
a) Pin 2 has no function
b) Pin 2 = input, e.g. for light/dark switching
c) Pin 2 = output, e.g. for an inverse signal
With sensors or type b), the basic switching type can be
changed by connecting pin 2 to +24 V or to ground [75].
For all other sensor types is the absolute rule: Leave
the relevant jumpers open!
Example:
The alternative label sensor pictured in [74] has an in-
verse output on pin 2. Therefore, JP 901 must be left
open.
Gen. 1
1) With the board in the pictured position
[75] Controlling pin2 at the sensor connector by placing JP901 resp.
JP902
JP 901
JP 902
Function
1)
Pin 2 of the sensor connector is not
connected (default setting)
1)
Pin 2 of the sensor connector is connected to
+24 V
1)
Pin 2 of the sensor connector is connected to
ground
[74] CPU board „Gen. 1“.
A
Position of the jumper JP901 (A) for the control of pin 2 of
the
alternative label sensor
B
Position of the jumper JP902 (B) for the control of pin 2 of
the
product photoelectric sensor
A6379
A
A
B