17 — Transducer
17–6
CX20/CX30/CX34 Service Manual
17.2
Testing
The transducer cannot be tested as a separate part and must be tested as part
of the unit.
17.3
A/D PCB
The A/D PCB receives the analogue signal from the transducer when weight is
applied to it. This signal is the change in resistance detected by the
transducer’s strain gauges. The A/D PCB converts this signal to digital form and
sends it to the main PCB.