Testing, start-up, diagnosis
AVENTICS
| INTERBUS | R412005655–BDL–001–AB
95
English
Systems with input/output modules:
3.
Connect the sensors to the input modules and the actuators
to the output modules.
4.
If a power module is present: connect the power supply
cable to the power module's POWER X10.
6
Testing, start-up, diagnosis
6.1
Testing
The functional reliability and operating method of the actuator/
sensor controls should be checked before start-up.
LED display on the
E24V-/16f-IB 16-position
input module
LED display on the
A24V-/0.5A-IB 8-position
output module
Table 19:
Status display on 16-position input module
LED
Color
Meaning
E0, E1, E2, E3, E4, E5,
E6, E7, E8, E9, E10,
E11, E12, E13, E14, E15
Yellow
Input signal level on high
Off
Input signal level on low
Table 20:
Status display on 8-position output module
LED
Color
Meaning
A0, A1, A2, A3,
A4, A5, A6, A7
Yellow
Output signal level on high
Off
Output signal level on low