Configuration
80
AVENTICS
| INTERBUS | R412005655–BDL–001–AB
4.2.2
Output data buffer assignment
A valve module is assigned either 2 bytes (up to 8 valves) or
4 bytes (up to 16 valves) in the output data buffer. This depends
on the S1/1 switch setting.
The output bytes from other existing modules then connect to
outputs.
Output data buffer
assignment
The number of bits upon output activation is equal to the
numbering of the M12x1 sockets on the input/output modules. If
the PLC address A7 is assigned to an output module with
8 outputs, then assign bit A7.3 to output 4 for this output module.
Table 9:
Modules with outputs
Modules with outputs
Number of output bytes assigned
1)
1)
Without single bit diagnosis
Valve terminal, up to 8 valves
2
Valve terminal, up to 16 valves
4
8-position output module
1 each