ACVMAX PARAMETERS FOR THE SPECIALIST
Information Items
Description
Boiler Status
Displays the current operating state of the Prestige. This is the same as the status line on the home screen.
Heating Call
Displays if a central heating call is present.
DHW Call
Displays if a domestic hot water call is present
Boiler Firing Rate
Displays the current firing rate of the Prestige
Ionization Current
Displays the current flame ionization current from the ignitor
Boiler Setpoint
Displays the current setpoint of the Prestige.
Supply Temp.
Displays the current supply temperature of the Prestige.
Return Temp.
Displays the current return temperature of the Prestige.
Boiler Flue Temp.
Displays the current flue temperature of the Prestige.
Outdoor Temp.
Displays the current outdoor temperature
DHW Storage Temp.
Displays the current DHW storage temperature when Indirect Water Heater Sensor is installed
External Modulation Signal
Displays the current external modulation signal being received from an external controller.
Pressure
Displays the system pressure.
CH Ignitions
Displays the number of central heating ignitions since the unit was installed. This counter increases in increments of twenty.
CH Runtime
Displays the number of hours the Prestige has run for a central heating call since the unit was installed.
DHW Ignitions
Displays the number of domestic hot water ignitions since the unit was installed. This counter increases in increments of twenty.
DHW Runtime
Displays the number of hours the Prestige has run for a domestic hot water call since the unit was installed.
Mix Zone Temperature
Displays the temperature of the low temperature mixed circuit