APPLIANCE DESCRIPTION AND OPERATION
CH & DHW Settings / Boiler Settings
Boiler Settings
Boiler Settings
Prestige Model
Solo (2 pumps)
Lockout Temp.
221°F [105°C]
Modbus Address
1
Pump settings
Ignition Level NAT
3100rpm
Prestige Model
Solo (2 pumps)
Solo/Excel. (3 way valve)
The
Boiler Settings
menu
contains settings related to boiler operation. Each line contains
a boiler setting followed by its current value. Four boiler settings are available.
Press the
UP
or
DOWN
buttons to scroll through the settings, then on
OK
to validate your
selection.
The
Prestige Model
menu allows to select the boiler type and access specific settings
for that appliance in other menus. The selection “Solo (2 pumps) is applicable to Prestige
42-50-75-100-120 Solo, and Solo/Excel. (3-way valve) is applicable to Prestige 24-32 Solo/
Excellence boilers.
Boiler Settings
Prestige Model
Solo (2 pumps)
Lockout Temp.
221°F [105°C]
Modbus Address
1
Pump settings
Ignition Level NAT
3100rpm
Lockout Temp.
39°C / 102°F
221°F [105°C]
The
Lockout Temp.
setting allows testing of the overheat thermostat function at a reduced
temperature. It temporarily decreases the overheat temperature of the appliance to 39°C
which allows a safe demonstration of the function.
Press the
UP
or
DOWN
buttons to scroll through the settings, then on
OK
to validate your
selection.
Default: 105°C
Boiler Settings
Prestige Model
Solo (2 pumps)
Lockout Temp.
221°F [105°C]
Modbus Address
1
Pump settings
Ignition Level
3100rpm
Modbus Address
1
0=BCST
247
This parameter sets the Modbus address of the appliance in a Modbus based communica-
tion system.
Press the
LEFT
or
RIGHT
buttons to adjust the settings, then on
OK
to validate your
selection.
Default: 1
Boiler Settings
Prestige Model
Solo (2 pumps)
Lockout Temp.
221°F [105°C]
Modbus Address
1
Pump settings
Ignition Level
3100rpm
Pump Settings
Current Pump Config
Modified
Preset Pump Config
Flexible Pump Config
The
Pump Settings
menu allows to choose the right pump configuration to the chosen
hydraulic configuration. There is a preset configuration mode and a flexible configuration
mode.
Press the
UP
or
DOWN
buttons to scroll through the options, then on
OK
to validate your
selection.